Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In this study, the PEG-Glu-Lys-Glu copolymer drug delivery system (GO/PEG-Glu-Lys-Glu) is prepared using glutamate-lysine-glutamate (Glu-Lys-Glu) modified polyethylene glycol (PEG) and connected graphene oxide nanosheets (GO). The multiple carboxyl groups of Glu-Lys-Glu and π-π interactions of GO can increase drug loading rate, and the fluorescence characteristics of GO could monitor the distribution of drug-loading systems in cells and the uptake of cells without the need for external dyes. Paclitaxel (PTX) is loaded reduction-responsive disulfide bonds as a model medicine to examine the drug delivery potential of GO/PEG-Glu-Lys-Glu. The results showed that the drug loading content of PEG-Glu-Lys-Glu and GO/PEG-Glu-Lys-Glu to PTX is 7.11% and 8.97%, and the loading efficiency is 71.05% and 89.68%, respectively. It's speculated that the π-π interaction between GO and PTX improved the drug-loading capacity and efficiency of GO/PEG-Glu-Lys-Glu. in a simulated drug release test, at 48 h, the release of PTX was 85.51% at pH 5.0, 65.12% and 38.32% at pH 6.5 and 7.4, respectively. The cytotoxicity assay results showed that GO/PEG-Glu-Lys-Glu cell inhibition rate to MCF-7 cells was 7.36% at 72 h. The cell inhibition rate of GO/PEG-Glu-Lys-Glu/PTX system at 72 h was 92%, equivalent to free PTX. Therefore, the GO/PEG-Glu-Lys-Glu drug delivery system has the characteristics of good biocompatibility and sustainable release of PTX, which is expected to be applied in the field of tumor therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/09205063.2023.2289244 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!