Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
It is crucial to have a reliable and sensitive method for separating common drugs used in SARS-CoV-2 pneumonia treatment protocols for ongoing treatment and upcoming investigations. This study presents an HPLC-FLD approach to analyze three co-administered medicines - remdesivir (RDV), hydroxychloroquine sulphate (HCQ), and levofloxacin hemihydrate (LVX) - in their pure forms, pharmaceutical preparations, and spiked human plasma. The HPLC-FLD analysis was conducted using a Symmetry® C18 column (100 mm × 4.6 mm ID, 3.5 μm particle size) at 40 °C, with (A) an aqueous mixture of 0.02 M phosphate buffer and 0.2% heptane-1-sulphonic acid sodium solutions (50 : 50) adjusted to pH 3, (B) acetonitrile, and (C) methanol as the mobile phase. The injection volume was 10 μL, and the flow rate was 1.5 mL min. The detection was done using a multi-wavelength excitation and emission fluorescence detector, with individual optimization for each drug. The drug separation time was less than 10 minutes, and the method showed sensitive and wide linearity ranges for all medicines, with values of more than 0.999. The impact of the mobile phase pH and flow rate on suitability parameters (retention time and number of theoretical plates) was studied. The method was found to be environmentally friendly based on GAPI and AGREE metrics. The validity of the method was evaluated following ICH and FDA guidelines.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d3ay01562a | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!