Background: Disc perforation (DP) is a severe type of Temporomandibular Disorder (TMD). DP may induce changes in the internal stresses of the temporomandibular joint (TMJ). Herein, this study attempts to investigate the biomechanical effects of different positions and sizes of DP on the TMJ using a biomechanical approach, to explore the mechanical pathogenesis of TMD.

Methods: Eleven three-dimensional finite element (FE)models of the TMJ were constructed based on CBCT imaging files of a patient with DP on the left side. These models included the disc with anterior displacement and discs with different locations and sizes of perforations on the affected disc. FE methods were conducted on these models.

Results: Anterior displacement of the disc leads to a significant increase in the maxim von Mises stress (MVMS) in both TMJs, with the affected side exhibiting a more pronounced effect. DP occurring at the posterior band and the junction between the disc and the bilaminar region has a greater impact on the MVMS of both TMJs compared to perforations at other locations. As the size of the perforation increases, both sides of the TMJs exhibit an increase in the magnitude of MVMS.

Conclusions: Unilateral disc anterior displacement results in an increased stress on both TMJs. Unilateral DP further affects the stress on both sides of the TMJs. TMD is a progressive condition, and timely intervention is necessary in the early stages to prevent the worsening of the condition.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10685656PMC
http://dx.doi.org/10.1186/s12903-023-03521-xDOI Listing

Publication Analysis

Top Keywords

anterior displacement
12
biomechanical effects
8
disc perforation
8
temporomandibular joint
8
finite element
8
disc anterior
8
mvms tmjs
8
sides tmjs
8
disc
7
tmjs
5

Similar Publications

Background: Retrograde superior ramus screw of pubis (SRSP) is a new kind of pelvic minimally invasive internal fixation apparatus developed by our team. The purpose of this study was to analyze the biomechanical stability of this new minimally invasive pelvic internal fixation device, and to provide this new device with theoretical basis for clinical application.

Methods: The Tile C1.

View Article and Find Full Text PDF

Analyzing corneal biomechanical response in orthokeratology with differing back optic zone diameter: A comparative finite element study.

Cont Lens Anterior Eye

March 2025

National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, China; National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou 325027, China; Oujiang Laboratory, Zhejiang Lab for Regenerative Medicine, Vision and Brain Health, Wenzhou 325101, China; Department of Ophthalmology, The Third Hospital of Mianyang, Sichuan Mental Health Center, Mianyang 621054, China. Electronic address:

Purpose: To investigate the impact of orthokeratology (ortho-k) lenses with different back optic zone diameter (BOZD) on the biomechanical response of the cornea, focusing on contact pressure, displacement, and stress distribution.

Method: Finite element models were developed to simulate varying corneal curvatures (39.0D, 42.

View Article and Find Full Text PDF

Background And Aims: Following an ankle sprain, clinical examination often reveals ankle dorsiflexion pain, which has been implicated as a risk factor for recurrent ankle sprains; however, the mechanism of ankle dorsiflexion pain has not been explored. Using magnetic resonance imaging (MRI), we evaluated the relationship between the limited dorsiflexion range of motion due to pain and the position of the talus. We investigated whether an anterior talofibular ligament (ATFL) tear affected ankle dorsiflexion.

View Article and Find Full Text PDF

Background: This study aims to compare the outcomes of two-level anterior cervical discectomy and fusion (ACDF) procedures using stand-alone cages versus cage and plate fixation in patients diagnosed with cervical disc herniation (CDH).

Materials And Methods: This retrospective analysis included 60 patients who underwent two-level ACDF procedures. Patients were divided into two groups: one treated with stand-alone cages and the other with cage and plate fixation.

View Article and Find Full Text PDF

Aim And Background: This study aimed to investigate the relationship between cervical spinal alignment and the center of gravity (COG) of the head in patients with Chiari malformation (CM) compared to healthy individuals. CM is characterized by the herniation of posterior fossa structures through the foramen magnum, potentially affecting head positioning and craniovertebral junction biomechanics. Understanding these biomechanical changes is crucial for improving diagnostic and treatment strategies.

View Article and Find Full Text PDF