Introduction: Interventional cardiac MRI in the context of the treatment of cardiac arrhythmia requires submillimeter image resolution to precisely characterize the cardiac substrate and guide the catheter-based ablation procedure in real-time. Conventional MRI receiver coils positioned on the thorax provide insufficient signal-to-noise ratio (SNR) and spatial selectivity to satisfy these constraints.

Methods: A small circular MRI receiver coil was developed and evaluated under different experimental conditions, including high-resolution MRI anatomical and thermometric imaging at 1.5 T. From the perspective of developing a therapeutic MR-compatible catheter equipped with a receiver coil, we also propose alternative remote active detuning techniques of the receiver coil using one or two cables. Theoretical details are presented, as well as simulations and experimental validation.

Results: Anatomical images of the left ventricle at 170 µm in-plane resolution are provided on beating heart from swine using a 2 cm circular receiver coil. Taking advantage of the increase of SNR at its vicinity (up to 35 fold compared to conventional receiver coils), real-time MR-temperature imaging can reach an uncertainty below 0.1°C at the submillimetric spatial resolution. Remote active detuning using two cables has similar decoupling efficiency to conventional on-site decoupling, at the cost of an acceptable decrease in the resulting SNR.

Discussion: This study shows the potential of small dimension surface coils for minimally invasive therapy of cardiac arrhythmia intraoperatively guided by MRI. The proposed remote decoupling approaches may simplify the construction process and reduce the cost of such single-use devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10643167PMC
http://dx.doi.org/10.3389/fcvm.2023.1249572DOI Listing

Publication Analysis

Top Keywords

receiver coil
20
interventional cardiac
8
cardiac arrhythmia
8
mri receiver
8
receiver coils
8
remote active
8
active detuning
8
receiver
7
coil
5
cardiac
5

Similar Publications

Purpose To assess the impact of scanner manufacturer and scan protocol on the performance of deep learning models to classify prostate cancer (PCa) aggressiveness on biparametric MRI (bpMRI). Materials and Methods In this retrospective study, 5,478 cases from ProstateNet, a PCa bpMRI dataset with examinations from 13 centers, were used to develop five deep learning (DL) models to predict PCa aggressiveness with minimal lesion information and test how using data from different subgroups-scanner manufacturers and endorectal coil (ERC) use (Siemens, Philips, GE with and without ERC and the full dataset)-impacts model performance. Performance was assessed using the area under the receiver operating characteristic curve (AUC).

View Article and Find Full Text PDF

A high security physical layer encryption scheme for dual-mode orthogonal frequency division multiplexing with index modulation (DM-OFDM-IM) in magnetic induction communication is proposed. The scheme utilizes DM-OFDM-IM, where subcarriers within each subblock are divided into two groups, each modulated by distinct signal constellations. DM-OFDM-IM leverages the sequential information from the modulated constellation to transmit extra information, leading to a substantial enhancement in spectral efficiency.

View Article and Find Full Text PDF

The Role of Artificial Intelligence in Predicting Optic Neuritis Subtypes From Ocular Fundus Photographs.

J Neuroophthalmol

December 2024

Division of Ophthalmology (EB-S, AS, AA-A, AS-B, DW, SS, FC), Department of Surgery, University of Calgary, Calgary, Canada; Department of Biomedical Engineering (CN), University of Calgary, Calgary, Canada; Departments of Neurology (LBDL) and Ophthalmology (LBDL), University of Michigan, Ann Arbor, Michigan; and Department of Clinical Neurosciences (SS, FC), University of Calgary, Calgary, Canada.

Background: Optic neuritis (ON) is a complex clinical syndrome that has diverse etiologies and treatments based on its subtypes. Notably, ON associated with multiple sclerosis (MS ON) has a good prognosis for recovery irrespective of treatment, whereas ON associated with other conditions including neuromyelitis optica spectrum disorders or myelin oligodendrocyte glycoprotein antibody-associated disease is often associated with less favorable outcomes. Delay in treatment of these non-MS ON subtypes can lead to irreversible vision loss.

View Article and Find Full Text PDF

Purpose: To investigate the safety and efficacy of endovascular embolization combined with external drainage for poor-grade ruptured cerebral aneurysms and risk factors.

Materials And Methods: Forty-six patients with poor-grade ruptured cerebral aneurysms treated with endovascular embolization combined with decompressive craniectomy and drainage were retrospectively enrolled.

Results: Coil embolization alone was performed in 29 (63.

View Article and Find Full Text PDF

Purpose: To investigate structural alterations in the thalamus in patients with primary trigeminal neuralgia and provide a detailed perspective on thalamic remodeling in response to chronic pain at the level of individual thalamic nuclei.  METHODS: We analyzed a sample of 62 patients with primary trigeminal neuralgia who underwent surgical treatment, along with 28 healthy participants. Magnetic resonance imaging (MRI) data were acquired using a 3T system equipped with a 16-channel receiver head coil.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!