Purpose: Several cases of inaccurate irradiation in brachytherapy have been reported, occurring similarly to external radiation. Due to a large dose per fraction in brachytherapy, inaccurate irradiation can seriously harm a patient. Although various studies have been conducted, systems that detect inaccurate irradiation in brachytherapy are not as developed as those for external irradiation. This study aimed to construct a system that analyzes the source dwell position during irradiation using computed tomography (CT) scout images. The novelty of the study was that by using CT scout images, high versatility and analysis of absolute coordinates can be achieved.
Material And Methods: A treatment plan was designed with an iridium-192 (Ir) source delivering radiation at two dwell positions in a tandem applicator. CT scout images were taken during irradiation, and acquired under different imaging conditions and applicator geometries. First, we confirmed whether a source was visible in CT scout images. Then, employing in-house MATLAB program, source dwell coordinates were analyzed using the images. An analysis was considered adequate when the resulting source dwell coordinates agreed with the treatment plan within ±1 mm, in accordance with AAPM TG56 guidelines for source dwell position accuracy.
Results: The source dwelling was visible in CT scout image, which was enlarged or reduced depending on applicator geometries. The applicator was enlarged by 127% when 130 mm away from the center of CT gantry. The analysis results using our in-house program were considered adequate; although, analysis parameters required adjustments depending on imaging conditions.
Conclusions: The proposed system can be easily implemented for image-guided brachytherapy and can analyze the absolute coordinates of source dwell position. Therefore, the system could be used for preventing inaccurate irradiation by verifying whether brachytherapy was performed properly.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10669917 | PMC |
http://dx.doi.org/10.5114/jcb.2023.132700 | DOI Listing |
Mil Psychol
December 2024
Aerospace Medicine Department, U.S. Air Force School of Aerospace Medicine, Wright-Patterson AFB, Ohio.
JACC Clin Electrophysiol
November 2024
Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium.
Med Phys
October 2024
Department of Radiation Oncology, National Cancer Center Hospital East, Chiba, Japan.
Background: Comprehensive quality assurance (QA) for a seamless workflow of high-dose-rate brachytherapy, from imaging to planning and irradiation, is uncommon, and QA of the source dwell position is performed in one- or two-dimensions. Gel dosimetry using magnetic resonance imaging (MRI) is effective in verifying the three-dimensional distribution of doses for image-guided brachytherapy (IGBT). However, MRI scanners are not readily accessible, and MRI scanning is time-consuming.
View Article and Find Full Text PDFJ Appl Clin Med Phys
October 2024
Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Canada.
Philos Trans R Soc Lond B Biol Sci
November 2024
Department of Applied Bioinformatics, Institute for Microbiology and Genetics, University of Goettingen, Goettingen 37077, Germany.
Phenolic compounds of land plants are varied: they are chemodiverse, are sourced from different biosynthetic routes and fulfil a broad spectrum of functions that range from signalling phytohormones, to protective shields against stressors, to structural compounds. Their action defines the biology of land plants as we know it. Often, their roles are tied to environmental responses that, however, impacted already the algal progenitors of land plants, streptophyte algae.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!