A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of Two Printed Pseudoisochromatic Tests for Color Vision Assessment. | LitMetric

Significance: The Waggoner PIP24 is a pseudoisochromatic test with a pattern similar to the Ishihara test. This study determined that the W-PIP24 can be used clinically to yield screening results (or sensitivity and specificity) comparable with the Ishihara.

Purpose: This study aimed to determine whether the W-PIP24 is equivalent to the Ishihara 38 edition pseudoisochromatic test in detecting red-green color vision defects. Also, the performance of each plate of the W-PIP24 in detecting the color vision defects relative to the Ishihara test was determined.

Methods: Sixty-three individuals with congenital red-green color vision defects and 57 with normal trichromacy were recruited. Participants were tested with both the Ishihara and W-PIP24. The first-order agreement coefficients were calculated for the Ishihara and W-PIP24. The results were also analyzed using specificity, sensitivity, efficiency, and predictive pass and fail values.

Results: The agreement between the W-PIP24 and Ishihara test using the recommended criterion of using all plates was perfect. The sensitivity, specificity, predictive pass, and predictive fail were 1.00 (95% confidence interval, 0.94 to 1.00).

Conclusions: This study showed that the W-PIP24 using a failure criterion of three or more errors on screening plates 1 to 15 is equivalent to the Ishihara test while screening for red-green color vision deficiency using a failure criterion of three or more errors on screening plates 1 to 17 of the Ishihara 38 edition.

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0000000000002087DOI Listing

Publication Analysis

Top Keywords

color vision
20
ishihara test
16
red-green color
12
vision defects
12
pseudoisochromatic test
8
ishihara
8
sensitivity specificity
8
equivalent ishihara
8
ishihara edition
8
ishihara w-pip24
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!