Portable and Rapid Fluorescence Turn-On Detection of Total Pepsin in Saliva Based on Strong Electrostatic Interactions.

Anal Chem

Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry, Sichuan University, Chengdu, Sichuan 610065, China.

Published: December 2023

AI Article Synopsis

  • Salivary pepsin is a potential diagnostic marker for gastroesophageal reflux disease (GERD), but its detection is complicated due to its activity being dependent on acidic conditions (pH ∼ 2) while saliva is neutral.
  • A new fluorescence assay has been developed to detect pepsin at neutral pH by leveraging its electrostatic interaction with SYBR Green, resulting in an increase in fluorescence intensity without needing active pepsin.
  • A smartphone-based device was created to enable quick and accurate pepsin detection in saliva, achieving results in just 3 minutes and a detection limit of 0.2 μg/mL, facilitating noninvasive GERD diagnosis.

Article Abstract

Salivary pepsin has been proposed as a promising diagnostic marker for gastroesophageal reflux disease (GERD). However, the activity of human pepsin is strongly influenced by pH, and the acidic condition (pH ∼ 2) is optimal, which is a contradiction for the pepsin detection kit based on its catalytic activity. Thus, its accurate quantification in saliva (neutral pH) by readily rapid tools with simplicity and low cost is still challenging. Herein, a convenient fluorescence assay has been developed for the rapid detection of pepsin at neutral pH based on its electrostatic interaction with SYBR Green (SG) rather than the bioactivity. At neutral pH, the positively charged SG fluorophore can be effectively adsorbed by the negatively charged pepsin due to the low isoelectric point (pI) and large molecular size of pepsin. Thus, the molecular rotation of SG is limited, and its fluorescence intensity is significantly increased. The strategy was further confirmed to have the same fluorescence response as that of normally active and inactivated pepsin. Due to the unique pI of pepsin, the fluorescence strategy is highly selective for pepsin compared to other proteins. On the basis of this strategy, a smartphone-based fluorescence capture device integrated with a programmed Python program was fabricated for both color recognition and the accurate detection of pepsin within 3 min. Under the optimal conditions, this turn-on sensor allowed for the on-site analysis of pepsin with a detection limit of 0.2 μg/mL. Moreover, this strategy was successfully used to assess salivary pepsin to aid in the noninvasive diagnosis of GERD.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acs.analchem.3c04723DOI Listing

Publication Analysis

Top Keywords

pepsin
13
salivary pepsin
8
pepsin detection
8
detection pepsin
8
fluorescence
6
detection
5
portable rapid
4
rapid fluorescence
4
fluorescence turn-on
4
turn-on detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!