Introduction: The aim of this study was to describe a simple technique for the implantation of toric intraocular lenses (IOLs) with increased stability during ophthalmic viscosurgical device (OVD) removal.

Methods: The technique was performed on 20 eyes with 20 patients (mean age: 77.9 ± 9.21 years). The patients had cataract surgery with implantation of a single-piece, acrylic IOL (AcrySof Toric IOL, SN6A; Alcon Laboratories, Inc.). The intraoperative IOL rotation during OVD removal, rotational error of toric IOL axis at 30 min and 24 h after surgery, and mean preoperative and postoperative IOP were evaluated. Images were captured before and after removal of OVD from surgical video, and used to evaluate intraoperative IOL rotation.

Results: The mean amount of IOL rotation during OVD removal with the current technique was 0.88 ± 0.93°, which was less than the 10.25 ± 5.50° previously reported for the conventional technique. The rotational error of toric IOL axis at 30 min and 24 h were 3.90 ± 3.71 and 3.05 ± 3.22°, respectively. The mean preoperative IOP and postoperative IOP were 13.84 ± 2.39 and 14.15 ± 4.68 mm Hg, respectively.

Conclusions: With the current technique, the toric IOL is stable during OVD removal and repositioning of the IOL during surgery is less likely to be required.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000535526DOI Listing

Publication Analysis

Top Keywords

toric iol
16
ovd removal
12
iol
9
simple technique
8
toric intraocular
8
ophthalmic viscosurgical
8
viscosurgical device
8
intraoperative iol
8
iol rotation
8
rotation ovd
8

Similar Publications

Objectives: To evaluate the efficacy, safety, and stability of EyeCryl Phakic intraocular lens (IOL) implantation.

Methodology: This retrospective study was conducted in Maghrabi Hospital in Medina to review 31 patients who underwent posterior chamber phakic IOL (EyeCryl Phakic IOL) for surgical correction of myopia or astigmatism. The data were collected from patient medical records after obtaining their consents.

View Article and Find Full Text PDF

Background: This study aims to comprehensively evaluate the predictive accuracy of six widely used toric intraocular lens (IOL) calculators in eyes undergoing cataract surgery with toric IOL implantation.

Methods: This retrospective study reviewed 53 eyes of 53 patients that underwent cataract extraction with toric IOL implantation using Zeiss 709 M. Six toric IOL calculators were evaluated: Barrett toric calculator (with predicted PCA, measured PCA, and TK), Kane formula (predicted PCA), and EVO 2.

View Article and Find Full Text PDF

Objective: Toric intraocular lens implantation has been used to correct corneal astigmatism during cataract surgery. The study aimed to compare the visual outcomes between manual vs markerless toric intraocular lens implantation in astigmatic correction.

Methods: The medical records of patients at American Eye Center who underwent phacoemulsification by multiple surgeons with insertion of monofocal or multifocal toric lenses via manual marking and markerless method from 2010-2019 were reviewed.

View Article and Find Full Text PDF

Background: The Eyhance Toric intraocular lens (IOL) builds upon the Tecnis Toric platform, initially associated with considerable post-operative rotational instability. Version 2, the Eyhance Toric IOL has been modified to enhance rotational stability. This study evaluates the post-operative rotational stability of the Eyhance Toric IOL compared to the Clareon Toric IOL, recognized for its stable performance.

View Article and Find Full Text PDF

Background: To determine whether accounting for posterior corneal surgically induced astigmatism (SIA) would improve toric intraocular lens power calculation prediction error.

Methods: A total of 189 eyes of 148 patients undergoing routine cataract surgery were included in the study. Standard and posterior keratometry were measured pre- and postoperatively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!