AI Article Synopsis

  • A study evaluated the safety and feasibility of implanting totally implantable venous access ports (TIVAPs) using an ultrasound-guided posterior approach to the internal jugular vein (IJV) in 88 oncology patients undergoing chemotherapy.
  • The procedure was highly successful, with a 100% overall success rate and a 96.59% first-attempt success rate, while average operation time was around 26.6 minutes and complications were minimal.
  • Results indicate that this approach is effective, enhances patient comfort, and reduces issues like catheter kinking, suggesting the need for larger studies to confirm findings.

Article Abstract

Background: To determine the feasibility and safety of ultrasound-guided totally implantable venous access port (TIVAP) implantation via the posterior approach of the internal jugular vein (IJV).

Methods: From September 2021 to August 2022, 88 oncology patients underwent ultrasound-guided implantation of TIVAPs via the posterior approach of the IJV for the administration of chemotherapy. The catheter tip was adjusted to be positioned at the cavoatrial junction under fluoroscopic guidance. Clinical data including surgical success, success rate for the first attempt, intraoperative, and postoperative complications were all collected and analyzed.

Results: All patients underwent successful surgery (100%), whereby 58 were via the right IJV and 30 via the left IJV, and the success rate for the first attempt was 96.59% (85/88). The operation time was 20 to 43 minutes, with an average of 26.59 ± 6.18 minutes with no intraoperative complications. The follow-up duration ranged from 1 to 12 months (mean = 5.28 ± 3.07) and the follow-up rate was 100%. The rate of postoperative complications was 4.55% (4/88), including port-site infection in two cases, fibrin sheath formation in one case, and port flip in one case. No other complications were observed during follow-up.

Conclusion: Ultrasound-guided TIVAP implantation via the posterior approach of the IJV is feasible, safe, and effective, with a low rate of intraoperative and postoperative complications. Not only was the curvature of the catheter device smooth, but patients were satisfied with the comfort and cosmetic appearance. Additionally, we could reduce the possible complications of pinching and kinking of the catheter by using this approach. Therefore, further large-sample, prospective, and randomized controlled trials are warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1097/JCMA.0000000000001030DOI Listing

Publication Analysis

Top Keywords

posterior approach
16
implantation posterior
12
postoperative complications
12
ultrasound-guided totally
8
totally implantable
8
implantable venous
8
venous access
8
approach internal
8
internal jugular
8
jugular vein
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!