A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effectiveness of a Novel Rapid Infusion Device and Clinician Education for Early Fluid Therapy by Emergency Medical Services in Sepsis Patients: A Pre-Post Observational Study. | LitMetric

Objective: Emergency medical services (EMS) clinicians are tasked with early fluid resuscitation for patients with sepsis. Traditional methods for prehospital fluid delivery are limited in speed and ease-of-use. We conducted a comparative effectiveness study of a novel rapid infusion device for prehospital fluid delivery in suspected sepsis patients.

Methods: This pre-post observational study evaluated a hand-operated, rapid infusion device in a single large EMS system from July 2021-July 2022. Prior to device deployment, EMS clinicians completed didactic and simulation-based device training. Data were extracted from the EMS electronic health record. Eligible patients included adults with suspected sepsis treated by EMS with intravenous fluids. The primary outcome was the proportion of patients receiving goal fluid volume (at least 500 mL) prior to hospital arrival. Secondary outcomes included in-hospital mortality, disposition, and length of stay. Multivariable logistic regression was used to compare outcomes between 6-month pre- and post-implementation periods (July-December 2021 and February-July 2022, respectively), adjusting for patient demographics, abnormal prehospital vital signs, and EMS transport interval.

Results: Of 1,180 eligible patients (552 in the pre-implementation period; 628 in the post-implementation period), the mean age was 72 years old, 45% were female, and 25% were minority race-ethnicity. Median (interquartile range) fluid volume (in mL) increased between the pre- and post-implementation periods (600 [400,1,000] and 850 [500-1,000], respectively). Goal fluid volume was achieved in 70% of pre-implementation patients and 82% of post-implementation patients. In adjusted analysis, post-implementation patients were significantly more likely to receive goal fluid volume than pre-implementation patients (adjusted odds ratio (aOR) 2.00, 95% confidence interval (CI) 1.51-2.66). Pre-post in-hospital mortality was not significantly different (aOR 0.91, 95% CI 0.59-1.39).

Conclusion: In a single EMS system, sepsis education and introduction of a rapid infusion device was associated with achieving goal fluid volume for suspected sepsis. Further research is needed to assess the clinical effectiveness of infusion device implementation to improve sepsis patient outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10903127.2023.2286292DOI Listing

Publication Analysis

Top Keywords

infusion device
20
fluid volume
20
rapid infusion
16
goal fluid
16
suspected sepsis
12
fluid
9
patients
9
novel rapid
8
early fluid
8
emergency medical
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!