Objective: The objective of this systematic review was to assess the clinical, economic, and health resource utilization outcomes associated with the use of prefilled syringes in medication administration compared with traditional preparation methods.

Data Sources: We conducted a systematic literature review to evaluate outcomes such as medication errors, wastage, time savings, and contamination in prefilled syringes. Our search encompassed multiple databases, including PubMed and Embase, for studies published between January 1, 2017, and November 1, 2022.

Study Selection And Data Extraction: Peer-reviewed publications meeting our inclusion criteria underwent rigorous screening, including title, abstract, and full-text article assessments, performed by two reviewers.

Data Synthesis: Among reviewed articles, 24 met our eligibility criteria. Selected studies were primarily observational (46%) and conducted in Europe (46%). Our findings indicated that prefilled syringes consistently reduced medication errors (by 10%-73%), adverse events (from 1.1 to 0.275 per 100 administrations), wastage (by up to 80% of drug), and preparation time (from 4.0 to 338.0 seconds) (ranges varied by drug type, setting, and dosage). However, there was limited data on contamination. Economically, prefilled syringes reduced waste and error rates, which may translate into overall savings.

Relevance To Patient Care And Clinical Practice: This review highlights the value of prefilled syringes, which can streamline medication delivery, save nursing time, and reduce preventable medication errors. Moreover, prefilled syringes have the potential to minimize medication wastage, optimizing resource utilization and efficiency in health care settings.

Conclusion And Relevance: Our findings provide new insights into clinical and economic benefits of prefilled syringe adoption. These benefits include improved medication delivery and safety, which can lead to time and cost reductions for health care departments, hospitals, and health systems. However, further real-world research on clinical and economic outcomes, especially in contamination, is needed to better understand the benefits of prefilled syringes.

Download full-text PDF

Source
http://dx.doi.org/10.1177/10600280231212890DOI Listing

Publication Analysis

Top Keywords

prefilled syringes
32
clinical economic
16
resource utilization
12
medication errors
12
prefilled
9
economic health
8
health resource
8
syringes
8
medication
8
medication administration
8

Similar Publications

Background: We evaluated UK nurses' preferences for pediatric hexavalent vaccine attributes.

Research Design And Methods: In a discrete-choice experiment study, 150 nurses chose between 2 hypothetical pediatric hexavalent vaccines with varying attribute levels (device type, plastic in packaging, time on the market, and time the vaccine can stay safely at room temperature) in a series of choice questions. Using random-parameters logit-model estimates, conditional relative attribute importance (CRAI) and odds ratios (ORs) were calculated.

View Article and Find Full Text PDF

Background: In the context of injectable biologic products approved or in development for chronic spontaneous urticaria (CSU), it is important to capture which treatment attributes matter most to patient and what trade-offs patients are willing to make.

Objectives: The CHOICE-CSU study aimed to quantify patient preferences toward injectable treatment attributes among patients with CSU, inadequately controlled by H1-antihistamines.

Methods: This was a two-phase cross-sectional patient preference study in adult patients with a diagnosis of CSU, inadequately controlled by H1-antihistamines.

View Article and Find Full Text PDF

Background: Intravitreal and intracameral administration of melphalan and topotecan (TPT) has shown its efficacy in the treatment of retinoblastoma over the last few years. Due to rapid hydrolysis, melphalan must be administered within the hour following reconstitution. With improved stability at room temperature and reduced ocular toxicity, TPT seems to be a promising candidate for production of prefilled syringes in terms of safety and efficiency of preparation and treatment administration.

View Article and Find Full Text PDF

[8.5 mm cannulas on IVODI prefilled syringes].

Ophthalmologie

January 2025

Augenklinik Petrisberg, Max-Planck-Str. 14-16, 54296, Trier, Deutschland.

View Article and Find Full Text PDF

Background: CT-P47 is a candidate tocilizumab biosimilar that is currently in clinical development. We assessed the usability of CT-P47 self-administration via auto-injector (AI) in patients with rheumatoid arthritis (RA).

Research Design And Methods: This was a 12-week, single-arm, open-label, multiple-dose, Phase 3 study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!