Background: Cardiac 15 O-water PET is a noninvasive method to evaluate epicardial and microvascular dysfunction and further quantitate absolute myocardial blood flow (MBF).

Aim: The aim of this study was to assess the impact of revascularization on MBF and myocardial flow reserve (MFR) assessed with 15 O-water PET and invasive flow and pressure measurements.

Methods: In 21 patients with single-vessel disease referred for percutaneous coronary intervention (PCI), serial PET perfusion imaging and fractional flow reserve (FFR), coronary flow reserve (CFR) and index of microcirculatory resistance (IMR) were performed during PCI and after 3 months.

Results: In the affected myocardium, stress MBF and MFR increased significantly from before revascularization to 3 months after revascularization: stress MBF 2.4 ± 0.8 vs. 3.2 ± 0.8; P  < 0.001 and MFR 2.5 ± 0.8 vs. 3.4 ± 1.1; P  = 0.004. FFR and CFR increased significantly from baseline to after revascularization and remained stable from after revascularization to 3-month follow-up: FFR 0.64 ± 0.20 vs. 0.91 ± 0.06 vs. 0.91 ± 0.07; P  < 0.001; CFR 2.4 ± 1.2 vs. 3.6 ± 1.9 vs. 3.6 ± 1.9; P  < 0.001, whereas IMR did not change significantly: 30.3 ± 22.9 vs. 30.1 ± 25.3 vs. 31.9 ± 25.2; P  = ns. After revascularization, an increase in stress MBF was associated with an increase in FFR ( r  = 0.732; P  < 0.001) and an increase in MFR ( r  = 0.499; P  = 0.021). IMR measured before PCI was inversely associated with improvement in stress MBF, ( r  = -0.616; P  = 0.004).

Conclusion: Recovery of myocardial perfusion after PCI was associated with an increase in FFR 3 months after revascularization. Microcirculatory dysfunction was associated with less improvement in myocardial perfusion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10833199PMC
http://dx.doi.org/10.1097/MCA.0000000000001308DOI Listing

Publication Analysis

Top Keywords

flow reserve
20
fractional flow
8
coronary flow
8
microcirculatory resistance
8
percutaneous coronary
8
coronary intervention
8
o-water pet
8
stress mbf
8
flow
7
reserve
5

Similar Publications

Background: Data on the predictive value of coronary computed tomography angiography-derived fractional flow reserve (CT-FFR) for long-term outcomes are limited.

Methods And Results: A retrospective pooled analysis of individual patient data was performed. Deep-learning-based CT-FFR was calculated.

View Article and Find Full Text PDF

Purposes: The objective was to evaluate the accuracy of a novel CT dynamic angiographic imaging (CT-DAI) algorithm for rapid fractional flow reserve (FFR) measurement in patients with coronary artery disease (CAD).

Materials And Methods: This retrospective study included 14 patients (age 58.5 ± 10.

View Article and Find Full Text PDF

Automated stenosis estimation of coronary angiographies using end-to-end learning.

Int J Cardiovasc Imaging

January 2025

Novo Nordisk Foundation Center for Protein Research, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.

The initial evaluation of stenosis during coronary angiography is typically performed by visual assessment. Visual assessment has limited accuracy compared to fractional flow reserve and quantitative coronary angiography, which are more time-consuming and costly. Applying deep learning might yield a faster and more accurate stenosis assessment.

View Article and Find Full Text PDF

Medical image-based diagnostic techniques have become increasingly common in the clinic. Estimating fractional flow reserve in coronary stenoses from medical image data is among the most prominent examples. The modeling techniques used in these clinical tools require rigorous experimental validation yet there is currently no standardized, public toolset to help assess model credibility.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!