Purpose: Although the optimal treatment for femoropopliteal (FP) drug-coated balloon (DCB) restenosis lesions remains debatable, the effectiveness of DCB repetition for DCB restenosis has been reported. However, the optimal DCB repetition strategy is not yet established. Thus, this study aimed to compare the clinical outcomes of high-dose DCB repetition with those of low-dose DCB repetition for FP DCB restenosis lesions.

Materials And Methods: This single-center, observational study used a clinical database of 677 consecutive patients undergoing FP endovascular intervention for symptomatic peripheral artery disease between December 2018 and December 2021. Of these patients, 89 cases treated with DCB repetition for FP DCB restenosis lesions were analyzed. The primary endpoint was recurrent restenosis (re-restenosis) and the secondary endpoints were recurrent target-lesion revascularization (TLR), re-occlusion, and major adverse limb events (MALE) obtained using propensity score matching. Interaction analysis was also performed to explore the effects of the baseline characteristics on the association between high- and low-dose DCB with restenosis risk.

Results: After propensity score matching, high-dose DCB demonstrated a significantly higher freedom from re-restenosis compared with low-dose DCB repetition at 1 year (90.4% vs 40.9%, p=0.034). In addition, freedom from re-TLR and MALE at 1 year was significantly higher in the high-dose DCB group (95.0% vs 53.3%, p=0.025; 95.0% vs 54.7%, p=0.025, respectively). Conversely, freedom rates from re-occlusion were not significantly different between the 2 groups (100.0% vs 84.0%, p=0.99). No baseline characteristics or perioperative outcomes had any significant interaction effect on the association of high-dose DCB versus low-dose DCB with restenosis risk.

Conclusion: For FP DCB restenosis lesions, high-dose DCB repetition offered more favorable outcomes than low-dose DCB repetition.

Clinical Impact: This study revealed that for femoropopliteal drug-coated balloon (DCB) restenosis lesions, high-dose DCB repetition obtained more favorable outcomes than low-dose DCB repetition. In addition, there was no significant interaction effect on the association of high- versus low-dose DCB with re-restenosis risk for the baseline characteristics and perioperative outcomes. This finding might be also a reason for choosing high-dose DCB repetition for FP DCB restenosis lesions in daily clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1177/15266028231214167DOI Listing

Publication Analysis

Top Keywords

dcb repetition
40
dcb restenosis
36
high-dose dcb
28
low-dose dcb
28
dcb
24
restenosis lesions
20
drug-coated balloon
16
repetition dcb
16
baseline characteristics
12
repetition
11

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!