Background: The MitraClip G4 system is a new iteration of the transcatheter edge-to-edge repair system. We assessed the impact of the G4 system on routine practice and outcomes in secondary mitral regurgitation (2°MR).

Methods and results: Consecutive patients with 2°MR treated with either the MitraClip G2 (n=89) or G4 (n=63) system between 2018 and 2021 were included. Baseline characteristics, procedures, and outcomes were compared. Inverse probability of treatment weighting and Cox regression were used to adjust for baseline differences. Baseline characteristics were similar, except for a lower surgical risk in the G4 group (Society of Thoracic Surgeons Predicted Risk of Mortality ≥8: 38.1% vs. 56.2%; P=0.03). In the G4 group, more patients had short (≤2 mm) coaptation length (83.7% vs. 54.0%; P<0.001) and fewer clips were used (17.5% vs. 36.0%; P=0.02). Acceptable MR reduction was observed in nearly all patients, with no difference between the G4 and G2 groups (100% vs. 97.8%, respectively; P=0.51). The G4 group had fewer patients with high transmitral gradients (>5mmHg; 3.3% vs. 13.6%; P=0.03). At 1 year, there was no significant difference between groups in the composite endpoint (death or heart failure rehospitalization) after baseline adjustment (10.5% vs. 20.2%; hazard ratio 0.39; 95% confidence interval 0.11-1.32; P=0.13).

Conclusions: The G4 system achieved comparable device outcomes to the early-generation G2, despite treating more challenging 2°MR with fewer clips.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.CJ-23-0503DOI Listing

Publication Analysis

Top Keywords

mitraclip system
8
system routine
8
routine practice
8
practice outcomes
8
secondary mitral
8
mitral regurgitation
8
baseline characteristics
8
system
6
impact mitraclip
4
outcomes
4

Similar Publications

Purpose: Advancements in minimally invasive technologies to decrease postoperative morbidity and recovery times represent a large opportunity for mitral valve repair operations. However, current technologies are unable to replicate gold standard surgical neochord implantation.

Methods: We developed a novel neochordal repair device, Minimally Invasive Ventricular Anchoring Neochordoplasty (MIVAN), which operates via transcatheter, trans-septal anchoring to the posterior ventricular wall.

View Article and Find Full Text PDF

Background: In patients with adult congenital heart disease (ACHD), significant atrioventricular valve regurgitation is an important risk factor for poor outcomes, such as heart failure. However, in many cases, transcatheter intervention may reduce the risk profile to avoid a high surgical risk.

Case Summary: A 44-year-old man with complex ACHD in the form of a double-inlet left ventricle, congenitally corrected transposition of the great arteries, pulmonary atresia, atrial septal defect, and patent ductus arteriosus was referred for the treatment of severe tricuspid regurgitation.

View Article and Find Full Text PDF

Leadless pacemakers (LPMs) offer an alternative for patients with challenging venous access or device infection history. Management of LPM battery depletion in frail patients presents unique challenges. We present the case of an 81-year-old frail woman with obstructive hypertrophic cardiomyopathy and complete heart block, previously treated with percutaneous transseptal myocardial ablation and a transvenous pacemaker, who received an LPM after device extraction for infection.

View Article and Find Full Text PDF

Objectives: To evaluate the cost-effectiveness of percutaneous repair (PR) for secondary mitral regurgitation.

Design: An economic evaluation using a time-varying Markov model comprising three states to assess the cost and effectiveness of PR added to guideline-directed medical treatment (GDMT) compared with GDMT alone. Clinical outcomes considered within the model were overall survival and heart failure (HF) hospitalisations (HFH), and the incremental cost-effectiveness ratio (ICER) was calculated.

View Article and Find Full Text PDF
Article Synopsis
  • * In a prospective study involving 95 subjects across 7 centers in Japan, the new system showed a high success rate in reducing MR and improving patient functional capacity.
  • * Results indicated durable outcomes with minimal adverse events, including a low one-year all-cause mortality rate of 9.5% and heart failure hospitalization at 18.9%.
View Article and Find Full Text PDF