Validation of a scanning technique with minimal compression for measuring muscle volume with freehand 3D ultrasound.

J Biomech

Nantes Université, Movement - Interactions - Performance, MIP, UR 4334, F-44000 Nantes, France; Institut Universitaire de France (IUF), France. Electronic address: https://www.univ-nantes.fr/antoine-nordez.

Published: January 2024

Freehand 3D ultrasound (3D-US) is a promising technique for measuring muscle volume but it requires gel pads or water tanks to limit probe compression on the skin which makes it hard to use in clinical applications. Our objectives were to measure the effect of different compressions on muscle volume in order to assess the clinical applicability of a minimal compression method for lower limb muscles. 4 muscles of the lower limb on 15 healthy volunteers were scanned with a new commercial freehand 3D-US setup accessible to clinical experimentators. Each muscle was scanned with 3 levels of compression: standard compression, minimal compression and gel pad (method validated against MRI). Volume was calculated using software segmentation tools. Acquisitions and segmentations were done by the same examiner. There was a significant impact of standard compression on volume measurements, but no difference between minimal compression and gel pad. Standard compression underestimated volume with a mean bias of 16 mL. For minimal compression, 75 % of measured differences were below the predefined clinically acceptable limits of 10 mL. Mean bias for this method was 1.1 mL. In conclusion, standard compression in freehand 3D-US induces a systematic bias in volume calculations. But, with a trained examiner and the necessary precautions to minimize compression, this bias could be abolished and become acceptable in clinical applications. When a high accuracy is required, gel pads could still be important to consider.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jbiomech.2023.111878DOI Listing

Publication Analysis

Top Keywords

minimal compression
20
standard compression
16
compression
12
muscle volume
12
measuring muscle
8
freehand ultrasound
8
gel pads
8
clinical applications
8
lower limb
8
freehand 3d-us
8

Similar Publications

Background: Malignant obstructive jaundice (MOJ) is characterized by the presence of malignant tumors infiltrating or compressing the bile duct, causing poor bile drainage, generalized yellowing, pain, itching, and malaise. MOJ is burdensome for both the society and the families of affected patients and should be taken seriously.

Aim: To evaluate the clinical effect of stent placement during endoscopic retrograde cholangiopancreatography for relieving MOJ and the efficacy of percutaneous transhepatic biliary drainage in terms of liver function improvement, complication rates, and long-term patient outcomes.

View Article and Find Full Text PDF

An 85-year-old woman with long-standing atrial fibrillation and severe tricuspid regurgitation presented with worsening symptoms and massive right atrial enlargement (RAE). The patient experienced shortness of breath even during minimal exertion, such as walking within her house, which significantly impacted her daily activities. Surgical intervention, including tricuspid valve replacement and right atrial plication (RAP), led to significant symptomatic relief and improved pulmonary function.

View Article and Find Full Text PDF

Sustainability and environmental protection are reshaping industries, including construction, where sustainability plays a crucial role in its influence on global resource consumption and waste management. The current study has developed a reusable cement material by photo-chemical surface modification of marble powder, achieved by reacting glycidyl methacrylate with carbonate functionality. This innovative modified marble powder boosts the reusability of construction materials, unlocking new possibilities for sustainable building practices.

View Article and Find Full Text PDF

Recently, 3-D porous architecture of the composites play a key role in cell proliferation, bone regeneration, and anticancer activities. The osteoinductive and osteoconductive properties of β-TCP allow for the complete repair of numerous bone defects. Herein, β-TCP was synthesized by wet chemical precipitation route, and their 3-D porous composites with HBO and Cu nanoparticles were prepared by the solid-state reaction method with improved mechanical and biological performances.

View Article and Find Full Text PDF

Characterization of Fatigue Properties of Fiber-Reinforced Polymer Composites Based on a Multiscale Approach.

Polymers (Basel)

January 2025

Department of Mechanical Engineering, Hanyang University, 222 Wangsimri-ro, Seongdong-gu, Seoul 04763, Republic of Korea.

This study presents a methodology for characterizing the constituent properties of composite materials by back-calculating from the laminate behavior under fatigue loading. Composite materials consist of fiber reinforcements and a polymer matrix, with the fatigue performance of the laminate governed by the interaction between these constituents. Due to the challenges in directly measuring the properties of individual fibers and the polymer matrix, a reverse-engineering approach was employed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!