The development of smart wearable solutions for monitoring daily life health status is increasingly popular, with chest straps and wristbands being predominant. This study introduces a novel sensorized T-shirt design with textile electrodes connected via a knitting technique to a Movesense device. We aimed to investigate the impact of stationary and movement actions on electrocardiography (ECG) and heart rate (HR) measurements using our sensorized T-shirt. Various activities of daily living (ADLs), including sitting, standing, walking, and mopping, were evaluated by comparing our T-shirt with a commercial chest strap. Our findings demonstrate measurement equivalence across ADLs, regardless of the sensing approach. By comparing ECG and HR measurements, we gained valuable insights into the influence of physical activity on sensorized T-shirt development for monitoring. Notably, the ECG signals exhibited remarkable similarity between our sensorized T-shirt and the chest strap, with closely aligned HR distributions during both stationary and movement actions. The average mean absolute percentage error was below 3%, affirming the agreement between the two solutions. These findings underscore the robustness and accuracy of our sensorized T-shirt in monitoring ECG and HR during diverse ADLs, emphasizing the significance of considering physical activity in cardiovascular monitoring research and the development of personal health applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10675781PMC
http://dx.doi.org/10.3390/s23229208DOI Listing

Publication Analysis

Top Keywords

sensorized t-shirt
24
daily living
8
stationary movement
8
movement actions
8
chest strap
8
physical activity
8
sensorized
6
t-shirt
6
t-shirt intarsia-knitted
4
intarsia-knitted conductive
4

Similar Publications

Stitched textile-based microfluidics for wearable devices.

Lab Chip

December 2024

Department of Fibre and Polymer Technology, School of Engineering Sciences in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikringen 56-58, SE-100 44, Stockholm, Sweden.

Thread-based microfluidics, which rely on capillary forces in threads for liquid flow, are a promising alternative to conventional microfluidics, as they can be easily integrated into wearable textile-based biosensors. We present here advanced textile-based microfluidic devices fabricated by machine stitching, using only commercially available textiles. We stitch a polyester "Coolmax®" yarn with enhanced wicking abilities into both hydrophobic fabric and hydrophobically treated stretchable fabric, that serve as non-wicking substrates.

View Article and Find Full Text PDF

Introduction: In this study, we used surface electromyography (EMG) electrodes in order to measure and compare activity in the neck, back and thigh muscles of soldiers wearing two different types of body armour. A secondary objective was to analyse shoulder and hip ranges of motion using inertial motion sensors.

Methods: Fourteen male soldiers were instructed to march 6 km on a treadmill while wearing different types of body armour.

View Article and Find Full Text PDF

Background: Wearables that measure vital parameters can be potential tools for monitoring patients at home during cancer treatment. One type of wearable is a smart T-shirt with embedded sensors. Initially, smart T-shirts were designed to aid athletes in their performance analyses.

View Article and Find Full Text PDF

Flexible Textile Sensors-Based Smart T-Shirt for Respiratory Monitoring: Design, Development, and Preliminary Validation.

Sensors (Basel)

March 2024

Research Unit of Measurements and Biomedical Instrumentation, Departmental of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy.

Respiratory rate (fR) monitoring through wearable devices is crucial in several scenarios, providing insights into well-being and sports performance while minimizing interference with daily activities. Strain sensors embedded into garments stand out but require thorough investigation for optimal deployment. Optimal sensor positioning is often overlooked, and when addressed, the quality of the respiratory signal is neglected.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!