This work presents a technique for fault detection and identification in centrifugal pumps (CPs) using a novel fault-specific Mann-Whitney test (FSU Test) and K-nearest neighbor (KNN) classification algorithm. Traditional fault indicators, such as the mean, peak, root mean square, and impulse factor, lack sensitivity in detecting incipient faults. Furthermore, for defect identification, supervised models rely on pre-existing knowledge about pump defects for training purposes. To address these concerns, a new centrifugal pump fault indicator (CPFI) that does not rely on previous knowledge is developed based on a novel fault-specific Mann-Whitney test. The new fault indicator is obtained by decomposing the vibration signature (VS) of the centrifugal pump hierarchically into its respective time-frequency representation using the wavelet packet transform (WPT) in the first step. The node containing the fault-specific frequency band is selected, and the Mann-Whitney test statistic is calculated from it. The combination of hierarchical decomposition of the vibration signal for fault-specific frequency band selection and the Mann-Whitney test form the new fault-specific Mann-Whitney test. The test output statistic yields the centrifugal pump fault indicator, which shows sensitivity toward the health condition of the centrifugal pump. This indicator changes according to the working conditions of the centrifugal pump. To further enhance fault detection, a new effect ratio (ER) is introduced. The KNN algorithm is employed to classify the fault type, resulting in promising improvements in fault classification accuracy, particularly under variable operating conditions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10675659 | PMC |
http://dx.doi.org/10.3390/s23229090 | DOI Listing |
Ann Biomed Eng
January 2025
BioCardioLab, Fondazione Toscana G. Monasterio, 54100, Massa, Italy.
Extracorporeal Membrane Oxygenation (ECMO) is a modality of extracorporeal life support which allows temporary support in cases of cardiopulmonary failure and cardiogenic shock. This study presents a valveless pump that works by the Liebau effect as a possible pumping system in ECMO circuits, replacing the current roller and centrifugal pumps. For this purpose, a mock circulatory loop emulating the haemodynamic of the right part of the heart has been constructed.
View Article and Find Full Text PDFMicrosyst Nanoeng
January 2025
Henry Samueli School of Engineering, University of California, Irvine, CA, USA.
In recent decades, electrokinetic handling of microparticles and biological cells found many applications ranging from biomedical diagnostics to microscale assembly. The integration of electrokinetic handling such as dielectrophoresis (DEP) greatly benefits microfluidic point-of-care systems as many modern assays require cell handling. Compared to traditional pump-driven microfluidics, typically used for DEP applications, centrifugal CD microfluidics provides the ability to consolidate various liquid handling tasks in self-contained discs under the control of a single motor.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
January 2025
Shenzhen Key Laboratory of Cardiovascular Disease, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, Guangdong Province, China.
Impeller radial gap is one of important parts within a blood pump, which may affect the hemodynamics and hemocompatibility. In this study, computational fluid dynamics method was performed to evaluate the impact of radial gap sizes. The volume of scalar shear stress decreased with radial gap sizes increasing.
View Article and Find Full Text PDFArtif Organs
January 2025
BioCirc Research Laboratory, School of Biomedical Engineering, Science, and Health Systems, Drexel University, Philadelphia, Pennsylvania, USA.
Background: Safe and effective pediatric blood pumps continue to lag far behind those developed for adults. To address this growing unmet clinical need, we are developing a hybrid, continuous-flow, magnetically levitated, pediatric total artificial heart (TAH). Our hybrid TAH design, the Dragon Heart (DH), integrates both an axial flow and centrifugal flow blood pump within a single, compact housing.
View Article and Find Full Text PDFJ Artif Organs
January 2025
Department of Artificial Organs, National Cerebral and Cardiovascular Center, 6-1 Kishibe-Shinmachi, Suita, Osaka, 5648565, Japan.
This review traces the evolution of centrifugal blood pumps in mechanical circulatory support (MCS) systems. Initially met with concerns over blood damage and thrombus formation, centrifugal pumps have become crucial components in ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO) due to their simplified drive mechanisms and adaptability. This paper outlines three generations of centrifugal pump development: first-generation pumps with sealing components, second-generation pumps utilizing pivot bearings, and third-generation pumps employing contactless bearings.