In the context of simulating precision laser interferometers, we use several examples to compare two wavefront decomposition methods-the Mode Expansion Method (MEM) and the Gaussian Beam Decomposition (GBD) method-for their precision and applicability. To assess the performance of these methods, we define different types of errors and study their properties. We specify how the two methods can be fairly compared and based on that, compare the quality of the MEM and GBD through several examples. Here, we test cases for which analytic results are available, i.e., non-clipped circular and general astigmatic Gaussian beams, as well as clipped circular Gaussian beams, in the near, far, and extremely far fields of millions of kilometers occurring in space-gravitational wave detectors. Additionally, we compare the methods for aberrated wavefronts and their interaction with optical components by testing reflections from differently curved mirrors. We find that both methods can generally be used for decomposing non-Gaussian beams. However, which method is more accurate depends on the optical system and simulation settings. In the given examples, the MEM more accurately describes non-clipped Gaussian beams, whereas for clipped Gaussian beams and the interaction with surfaces, the GBD is more precise.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10674269PMC
http://dx.doi.org/10.3390/s23229024DOI Listing

Publication Analysis

Top Keywords

gaussian beams
16
non-gaussian beams
8
beams
6
gaussian
5
method comparison
4
comparison simulating
4
simulating non-gaussian
4
beams diffraction
4
diffraction precision
4
precision interferometry
4

Similar Publications

Objective Applying carbon ion beams, which have high linear energy transfer and low scatter within the human body, to Spatially Fractionated Radiation Therapy (SFRT) could benefit the treatment of deep-seated or radioresistant tumors. This study aims to simulate the dose distributions of spatially fractionated beams (SFB) to accurately determine the delivered dose and model the cell survival rate following SFB irradiation. Approach Dose distributions of carbon ion beams are calculated using the Triple Gaussian Model.

View Article and Find Full Text PDF

We derive the Goos-Hänchen (GH) and Imbert-Fedorov (IF) shifts of random electromagnetic beams with arbitrary state and degree of polarization and spatial coherence. Further, we demonstrate the general formalism by calculating analytic expressions for the GH and IF shifts of an electromagnetic Gaussian Schell-model (EGSM) beam and show that the GH shifts may exist irrespective of the degree and state of polarization of the beam, while the IF shifts vanish when the beam is either s or p polarized or completely unpolarized. In addition, the spatial coherence width of the EGSM beam is found to influence only the angular GH and IF shifts.

View Article and Find Full Text PDF

Purpose: The spot size of scanned particle beams is of crucial importance for the correct dose delivery and, therefore, plays a significant role in the quality assurance (QA) of pencil beam scanning ion beam therapy.

Materials And Methods: This study compares 5 detector types-radiochromic film, ionization chamber (IC) array, flat panel detector, multiwire chamber, and IC-for measuring the spot size of proton and carbon ion beams.

Results: Variations of up to 30% were found between detectors, underscoring the impact of detector choice on QA outcomes.

View Article and Find Full Text PDF

Objective Applying carbon ion beams, which have high linear energy transfer and low scatter within the human body, to Spatially Fractionated Radiation Therapy (SFRT) could benefit the treatment of deep-seated or radioresistant tumors. This study aims to simulate the dose distributions of spatially fractionated beams (SFB) to accurately determine the delivered dose and model the cell survival rate following SFB irradiation. Approach Dose distributions of carbon ion beams are calculated using the Triple Gaussian Model.

View Article and Find Full Text PDF

Background: Boron neutron capture therapy (BNCT) is an innovative binary form of radiation therapy with high selectivity towards cancer tissue based on the neutron capture reaction B(n,α)Li, consisting in the exposition of patients to neutron beams after administration of a boron compound with preferential accumulation in cancer cells. The high linear energy transfer products of the ensuing reaction deposit their energy at the cell level, sparing normal tissue. Although progress in accelerator-based BNCT has led to renewed interest in this cancer treatment modality, in vivo dose monitoring during treatment still remains not feasible and several approaches are under investigation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!