Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This paper proposes a two-dimensional precision level for real-time measurement using a zoom fast Fourier transform (zoom FFT)-based decoupling algorithm that was developed and integrated in an FPGA. This algorithm solves the contradiction between obtaining high resolution and obtaining high measurement speed, and achieves both high angle-resolution measurement and real-time measurement. The proposed level adopts a silicone-oil surface as the angle-sensitive interface and combines the principle of homodyne interference. By analyzing the frequency of the interference fringes, the angle variation can be determined. The zoom-FFT-based decoupling algorithm improves the system's frequency resolution of the interference fringes, thereby significantly enhancing the angle resolution. Furthermore, this algorithm improves the efficiency of angle decoupling, while the angle decoupling process can also be transplanted to the board to realize real-time measurement of the level. Finally, a prototype based on the level principle was tested to validate the effectiveness of the proposed method. The principle analysis and test results showed that the angle resolution of the prototype improved from 9 arcsec to about 0.1 arcsec using this angle-solution method. At the same time, the measurement repeatability of the prototype was approximately ±0.2 arcsec. In comparison with a commercial autocollimator, the angle measurement accuracy reached ±0.6 arcsec.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10673262 | PMC |
http://dx.doi.org/10.3390/mi14112028 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!