A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Selective Sensing in Microbial Fuel Cell Biosensors: Insights from Toxicity-Adapted and Non-Adapted Biofilms for Pb(II) and Neomycin Sulfate Detection. | LitMetric

This study introduces the utilization of self-powered microbial fuel cell (MFC)-based biosensors for the detection of biotoxicity in wastewater. Current MFC-based biosensors lack specificity in distinguishing between different pollutants. To address this limitation, a novel approach is introduced, capitalizing on the adaptive capabilities of anodic biofilms. By acclimating these biofilms to specific pollutants, an enhancement in the selectivity of MFC biosensors is achieved. Notably, electrochemically active bacteria (EAB) were cultivated on 3D porous carbon felt with and without a model toxicant (target analyte), resulting in the development of toxicant-resistant anodic biofilms. The model toxicants, Pb ions and the antibiotic neomycin sulfate (NS), were deployed at a concentration of 1 mg L during MFC operation. The influence of toxicity on biofilm growth and power production was investigated through polarization and power density curves. Concurrently, the electrochemical activity of both non-adapted and toxicity-adapted biofilms was investigated using cyclic voltammetry. Upon maturation and attainment of peak powers, the MFC reactors were evaluated individually as self-powered biosensors for pollutant detection in fresh wastewater, employing the external resistor (ER) mode. The selected ER, corresponding to the maximum power output, was positioned between the cathode and anode of each MFC, enabling output signal tracking through a data logging system. Subsequent exposure of mature biofilm-based MFC biosensors to various concentrations of the targeted toxicants revealed that non-adapted mature biofilms generated similar current-time profiles for both toxicity models, whereas toxicity-adapted biofilms produced distinctive current-time profiles. Accordingly, these results suggested that merely by adapting the anodic biofilm to the targeted toxicity, distinct and identifiable current-time profiles can be created. Furthermore, these toxicity-adapted and non-adapted biofilms can be employed to selectively detect the pollutant via the differential measurement of electrical signals. This differentiation offers a promising avenue for selective pollutant detection. To the best of our current knowledge, this approach, which harnesses the natural adaptability of biofilms for enhanced sensor selectivity, represents a pioneering effort in the realm of MFC-based biosensing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10673119PMC
http://dx.doi.org/10.3390/mi14112027DOI Listing

Publication Analysis

Top Keywords

current-time profiles
12
biofilms
9
microbial fuel
8
fuel cell
8
toxicity-adapted non-adapted
8
non-adapted biofilms
8
neomycin sulfate
8
mfc-based biosensors
8
anodic biofilms
8
mfc biosensors
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!