Bond Wire Fatigue of Au, Cu, and PCC in Power LED Packages.

Micromachines (Basel)

Department Energy and Environment, Applied Electronics and Photonics, University of Applied Sciences Burgenland, Campus 1, 7000 Eisenstadt, Austria.

Published: October 2023

Bond wire failure, primarily wire neck breakage, in power LED devices due to thermomechanical fatigue is one of the main reliability issues in power LED devices. Currently, the standard testing methods to evaluate the device's lifetime involve time-consuming thermal cycling or thermal shock tests. While numerical or simulation methods are used as convenient and quick alternatives, obtaining data from material lifetime models with accurate reliability and without experimental fatigue has proven challenging. To address this issue, a mechanical fatigue testing system was developed with the purpose of inducing mechanical stresses in the critical region of the bond wire connection above the ball bond. The aim was to accelerate fatigue cracks at this bottleneck, inducing a similar failure mode as observed during thermal tests. Experimental investigations were conducted on Au, Cu, and Pd-coated Cu bonding wires, each with a diameter of 25 µm, using both low- and high-frequency excitation. The lifetime of the wire bond obtained from these tests ranged from 100 to 1,000,000 cycles. This proposed testing method offers material lifetime data in a significantly shorter timeframe and requires minimal sample preparation. Additionally, finite element simulations were performed to quantify the stresses at the wire neck, facilitating comparisons to conventional testing methods, fatigue test results under various operating conditions, material models, and design evaluations of the fine wire bond reliability in LED and microelectronic packages.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10672991PMC
http://dx.doi.org/10.3390/mi14112002DOI Listing

Publication Analysis

Top Keywords

bond wire
12
power led
12
wire neck
8
led devices
8
testing methods
8
material lifetime
8
wire bond
8
bond
6
fatigue
6
wire
6

Similar Publications

This study presents the design and experimental evaluation of advanced corrosion protection coatings for application on prestressing strands which are the core constituents of prestressed concrete structures such as bridges. Variety of self-heal coatings embodying corrective and protective phenomena in response to the degrading effects of corrosion have been designed and tested in simulated aggressive weathering conditions. Standard 7-wire prestressing strands coated with self-heal epoxy, self-heal toughened epoxy and hybrid epoxy coating systems were subjected to salt fog spray up to a duration of 2500 h, and 3M CalCl, 3M NaOH, saturated Ca(OH) solutions and distilled water up to 45 days duration.

View Article and Find Full Text PDF

This study introduces high-strength non-prestressed steel strands as reinforcement materials into Engineered Cementitious Composites (ECCs) and developed a novel high-strength stainless-steel-strand-mesh (HSSWM)-reinforced ECC with enhanced toughness and corrosion resistance. The bonding performance between HSSWM and an ECC is essential for facilitating effective cooperative behavior. The bond behavior between the HSSWM and ECC was investigated through theoretical analysis.

View Article and Find Full Text PDF

Microresonator photonic wire bond integration for Kerr-microcomb generation.

Sci Rep

November 2024

FAST Labs™, BAE Systems, 130 Daniel Webster Hwy., Merrimack, 03054, NH, USA.

Extremely high-Q microresonators provide an attractive platform for a plethora of photonic applications including optical frequency combs, high-precision metrology, telecommunication, microwave generation, narrow linewidth lasers, and stable frequency references. Moreover, the desire for compactness and a low power threshold for nonlinear phenomena have spurred investigation into integrated and scalable solutions. Historically, crystalline microresonators with Q ∼ 10 were one of the first material platforms providing unprecedented optical performance in a small form factor.

View Article and Find Full Text PDF

Different Wire Surface Treatments on Adhesion Efficacy of Orthodontic Fixed Retainer: An Study.

J Contemp Dent Pract

July 2024

Department of Orthodontic, Faculty of Dentistry, Mansoura University, Mansoura, Egypt, ORCID: https://orcid.org/0000-0002-5109-4313.

Aim: This study assesses the impact of surface treatment with sandblasting and Z-primer on the adhesion efficacy of fixed lingual retainers.

Materials And Methods: Dead soft stainless steel wire 0.016 × 0.

View Article and Find Full Text PDF

This study investigates the shear bond strength between four widely used façade stones-travertine, granite, marble, and crystalline marble-and concrete substrates, with a particular focus on the role of polypropylene fibers in adhesive mortars. The research evaluates the effects of curing duration, fiber dosage, and mechanical anchorage on bond strength. Results demonstrate that Z-type anchorage provided the highest bond strength, followed by butterfly-type and wire tie systems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!