Objective: To assess and compare the effects of two pediatric anti-asthmatic medication doses on the microhardness of enamel and microhardness, surface roughness and color of restorative materials.

Methods: Human enamel samples and packable and flowable composite restorations were used. The samples were exposed to Salbutamol (0.6 mL/6 mL saline) and Budesonide (2 mL/2 mL saline) via a custom-made chamber connected to a nebulizer. Medication administration was conducted for 10 days. The samples were brushed with an electronic brush in a continuous and circular mode for 10 s after 10 min of medication administration. Assessments of microhardness, surface roughness and color were carried out at three different time intervals: baseline (T), 5 days (T) and 10 days (T). One-way analysis of variance (ANOVA), a two-sample t-test and a Bonferroni multiple comparison test were used to analyze the data and compare between the groups.

Results: Both medications significantly ( < 0.05) decreased the microhardness of the enamel and composite samples after 10 days. Both medications lowered the surface roughness of both types of composite with a greater effect observed after 10 days of Budesonide administration ( < 0.05). Both medications had comparable detectable color change on both types of composite with a greater effect observed after 10 days of Budesonide administration ( < 0.05).

Conclusion: Salbutamol and Budesonide significantly decreased microhardness in the enamel samples. Both medications affected the properties of packable and flowable composites. The packable composite showed more resistance to microhardness changes. Both medications showed a clinically detectable change in the color of packable and flowable composites.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10675679PMC
http://dx.doi.org/10.3390/pharmaceutics15112527DOI Listing

Publication Analysis

Top Keywords

packable flowable
16
surface roughness
16
flowable composites
12
microhardness surface
12
roughness color
12
microhardness enamel
12
salbutamol budesonide
8
enamel samples
8
medication administration
8
decreased microhardness
8

Similar Publications

Color Stability of Different Restorative Approaches for the Masking of Silver Diamine Fluoride after Thermal Aging.

Int J Clin Pediatr Dent

September 2024

Department of Biomedical Sciences, School of Dental Medicine, University of Nevada, Las Vegas, Nevada, USA.

Aim: The present study aims to evaluate the color stability of different masking modalities of silver diamine fluoride (SDF) on extracted carious teeth after thermal aging.

Methods And Results: One hundred and eight recently extracted carious permanent teeth were used. All sample teeth had SDF applied over the carious lesion.

View Article and Find Full Text PDF

Evaluation of the effect of aging on the shear bond strength between old composite resin restoration and the repair composite resin: an in-vitro study.

Minerva Dent Oral Sci

November 2024

Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Saveetha University, Chennai, Tamil Nadu, India -

Background: The current study aimed to evaluate the effect of aging on the repair bond strength between old composite resin and repaired composite resin and to evaluate which type of repair composite material provides better bond strength in different time durations.

Methods: Eighty nano-hybrid composite specimens were randomly divided into four groups (N.=20) and exposed to accelerated aging from 0 to 2 years.

View Article and Find Full Text PDF

This study aimed to test the load to fracture of flowable and high viscosity bulk-fill composites compared to a convetional (packable) composite used to build up pulpless teeth. 45 endodontically treated premolars were restored with fiber posts then divided into three groups (N = 15) according to the core build-up material. SDR group: (Smart Dentine Replacement), (BF): Filtek One Bulk Fill and (CC) Filtek Z350 packable composite.

View Article and Find Full Text PDF

This in vitro study aimed to evaluate surface roughness and wear of highly filled flowables and traditional packable composites. Additionally, the effect of polymerization time on these parameters was evaluated. Two flowable higly filled composites (CMf-Clearfil Majesty ES flow-low viscosity, Kuraray and GUf-Gaenial Universal Injectable, GC) and two packable composites (CM-Clearfil Majesty ES-2, Kuraray and GU-Gaenial A'CHORD, GC) were used to create 160 specimens (n = 40;8 × 6 × 4mm).

View Article and Find Full Text PDF

Bacterial adhesion and surface roughness of particulate-filled and short fiber-reinforced composites.

Odontology

September 2024

Department of Biomaterials Science and Turku Clinical Biomaterial Center, TCBC, Institute of Dentistry, University of Turku, Turku, Finland.

The objective of the study was to assess the initial adhesion of Streptococcus mutans (S. mutans) and surface roughness of different particulate-filled (PFC) and short fiber-reinforced (SFRC) composites. Five PFC composites (CeramX Universal, Filtek Universal, Omnichroma, Tetric Prime and Venus Diamond) and four SFRC composites (everX Posterior, everX Flow Bulk, everX Flow Dentin and experimental packable SFRC) were tested in this study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!