Background: The use of inert gas rebreathing for the non-invasive cardiac output measurement has produced measurements comparable to those obtained by various other methods. However, there are no guidelines for the inert gas rebreathing method during a cardiopulmonary exercise test (CPET). In addition, there is also a lack of specific standards for assessing the non-invasive measurement of cardiac output during CPET, both for healthy patients and those suffering from diseases and conditions.
Aim: This systematic review aims to describe the use of IGR for a non-invasive assessment of cardiac output during cardiopulmonary exercise testing and, based on the information extracted, to identify a proposed CPET report that includes an assessment of the cardiac output using the IGR method.
Methods: This systematic review was conducted by PRISMA (Preferred Reporting Items for Systematic Reviews and Meta Analyses) guidelines. PubMed, Web of Science, Scopus, and Cochrane Library databases were searched from inception until 29 December 2022. The primary search returned 261 articles, of which 47 studies met the inclusion criteria for this review.
Results And Conclusions: This systematic review provides a comprehensive description of protocols, indications, technical details, and proposed reporting standards for a non-invasive cardiac output assessment using IGR during CPET. It highlights the need for standardized approaches to CPET and identifies gaps in the literature. The review critically analyzes the strengths and limitations of the studies included and offers recommendations for future research by proposing a combined report from CPET-IGR along with its clinical application.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10671909 | PMC |
http://dx.doi.org/10.3390/jcm12227154 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!