Long-Term Clinical Outcomes of Ahmed Valve Implantation in Aniridic Glaucoma.

Biomedicines

Clinical Department of Ophthalmology, District Railway Hospital, 40-760 Katowice, Poland.

Published: November 2023

Background: This study assessed the efficacy and safety of Ahmed valve implantation in patients with aniridic glaucoma for three consecutive years.

Methods: Six adult patients (seven eyes) with Ahmed valve (AV) implants for aniridic glaucoma were enrolled in the study. The primary outcome measures were intraocular pressure reduction, glaucoma medication use, success rates, and visual acuity after AV implantation. A 30% reduction in IOP from baseline without the need for re-intervention was considered an effective treatment. The cessation of antiglaucoma medications was defined as complete success. Intraoperative and postoperative complications were included as secondary outcome measures. Measurements were performed preoperatively, at the first week, and 1, 3, 6, 12, 18, 24, 30, and 36 months postoperatively.

Results: A total of seven eyes (6 patients) were evaluated 36 months after AV implantation. The mean ± SD values of IOP preoperatively at 1 day, 1 week, and 1, 3, 6, 12, 18, 24, 30, and 36 months postoperatively were 30.4 ± 4.0 mmHg, 14.6 ± 4.6 mmHg, 16.1 ± 4.6 mmHg, 20.7 ± 7.0 mmHg, 14.5 ± 2.7 mmHg, 16.5 ± 5.9 mmHg, 16.2 ± 4.0 mmHg, 16.3 ± 4.3 mmHg, 17.2 ± 10.1 mmHg, 17.6 ± 6.9 mmHg, and 18.2 ± 5.5 mmHg, respectively. At the last follow up, the mean IOP was reduced by 40.2%. The qualified success rate was 85.7%. One patient (one eye) at the last follow-up visit did not require antiglaucoma medications, resulting in a complete success rate of 14.3%. Intra- and postoperative mild or moderate subconjunctival bleeding was observed in all the patients. No other major/minor intraoperative or postoperative complications were noted.

Conclusions: In long-term follow up, the AV implantation procedure is well-tolerated and relatively safe for reducing IOP in adult aniridia patients with glaucoma. These results should be validated through studies involving a larger patient cohort.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10669343PMC
http://dx.doi.org/10.3390/biomedicines11112996DOI Listing

Publication Analysis

Top Keywords

ahmed valve
12
aniridic glaucoma
12
mmhg
11
valve implantation
8
outcome measures
8
antiglaucoma medications
8
complete success
8
intraoperative postoperative
8
postoperative complications
8
week months
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!