Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Inguinal hernia (IH) repair is a common procedure in the daily practice of pediatric surgeons. In a developing country with limited facilities, it is important to be able to predict and diagnose contralateral patent processus vaginalis (CPPV) to avoid the risk and cost of further surgery.
Objectives: To assess the accuracy of ultrasound for the detection of CPPV, using laparoscopic evaluation as a confirmatory test. We also looked for various predictors of CPPV in our study population.
Methods: 141 patients were included in this 2-year, cross-sectional prospective study. Inclusion criteria were unilateral inguinal hernia elective patients with no major comorbidities and aged between 2 months and 8 years. Each patient was assessed in outpatient clinics and then a pre-operative ultrasound was conducted. This was followed by laparoscopic evaluation during repair of the hernia.
Results: Of the 141 patients included, 110 (78%) were males, 121 (85.9%) were born at full term, and 96 (68.1) had right-sided hernia. Mean age was 2.64 ± 1.9 years. Ultrasound was 85.7% sensitive in the detection of CPPV, 90.8% specific, and 90.1% accurate. In our analysis of patients younger than 1 year, right-sided hernia and defect size more than 10 mm were statistically significant predictors for a CPPV.
Conclusions: Ultrasound has a high accuracy profile and is a useful alternative in limited resource settings with restricted access to minimally invasive surgery for the prediction of CPPV. Patients younger than 1 year with a right-sided hernia or a manifested hernia defect larger than 10 mm are at a higher risk of having a CPPV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00383-023-05576-x | DOI Listing |