Background: Positron emission tomography (PET) has demonstrated utility for diagnostic and prognostic assessment of cardiac allograft vasculopathy (CAV) but has not been evaluated in the first year after transplant.

Objectives: The authors sought to evaluate CAV at 1 year by PET myocardial blood flow (MBF) quantification.

Methods: Adults at 2 institutions enrolled between January 2018 and March 2021 underwent prospective 3-month (baseline) and 12-month (follow-up) post-transplant PET, endomyocardial biopsy, and intravascular ultrasound examination. Epicardial CAV was assessed by intravascular ultrasound percent intimal volume (PIV) and microvascular CAV by endomyocardial biopsy.

Results: A total of 136 PET studies from 74 patients were analyzed. At 12 months, median PIV increased 5.6% (95% CI: 3.6%-7.1%) with no change in microvascular CAV incidence (baseline: 31% vs follow-up: 38%; P = 0.406) and persistent microvascular disease in 13% of patients. Median capillary density increased 30 capillaries/mm (95% CI: -6 to 79 capillaries/mm). PET myocardial flow reserve (2.5 ± 0.7 vs 2.9 ± 0.8; P = 0.001) and stress MBF (2.7 ± 0.6 vs 2.9 ± 0.6; P = 0.008) increased, and coronary vascular resistance (CVR) (49 ± 13 vs 47 ± 11; P = 0.214) was unchanged. At 12 months, PET and PIV had modest correlation (stress MBF: r = -0.35; CVR: r = 0.33), with lower stress MBF and higher CVR across increasing PIV tertiles (all P < 0.05). Receiver-operating characteristic curves for CAV defined by upper-tertile PIV showed areas under the curve of 0.74 for stress MBF and 0.73 for CVR.

Conclusions: The 1-year post-transplant PET MBF is associated with epicardial CAV, supporting potential use for early noninvasive CAV assessment. (Early Post Transplant Cardiac Allograft Vasculopahty [ECAV]; NCT03217786).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcmg.2023.10.003DOI Listing

Publication Analysis

Top Keywords

stress mbf
16
pet myocardial
12
cardiac allograft
12
myocardial blood
8
blood flow
8
assessment early
8
allograft vasculopathy
8
cav
8
post-transplant pet
8
intravascular ultrasound
8

Similar Publications

Myocardial blood flow mechanism of mental stress-induced myocardial ischemia in women with ANOCA.

iScience

December 2024

The Second Clinical Medical College, Jinan University (Shenzhen People's Hospital, The First Affiliated Hospital, Southern University of Science and Technology), Shenzhen, China.

Article Synopsis
  • Mental stress-induced myocardial ischemia (MSIMI) significantly increases cardiovascular events, yet its precise mechanisms related to myocardial blood flow (MBF) are not fully understood.
  • A study using cardiac positron emission tomography (PET-CT) revealed that women with angina but no obstructive coronary artery disease (ANOCA) had a much higher prevalence of MSIMI compared to healthy controls.
  • Results showed that these participants had lower MBF and coronary flow reserves, indicating that impaired coronary microvascular function plays a crucial role in the development of MSIMI in individuals with ANOCA.
View Article and Find Full Text PDF

Objectives: This study aimed to investigate the prognostic significance of stress dynamic myocardial CT perfusion imaging (CTP) and determine whether it has incremental advantages over coronary computed tomography angiography (CTA)-derived parameters.

Methods: This prospective multicenter study included patients with suspected coronary artery disease who had undergone coronary CTA and CTP and were followed for 6 years. The endpoint was time-to-first major adverse cardiovascular event (MACE).

View Article and Find Full Text PDF

Background: Different bar construction techniques will affect the bar passive fitness, which may induce stresses or strain on the implant and/or tightening screw and sequentially may affect the biting force and patient satisfaction.

Aim Of The Study: This clinical investigation assessed patient satisfaction and maximum biting force (MBF) using three differently constructed (conventional casting, milling, and 3D printing CAD/CAM techniques) cobalt-chromium (Co-Cr) bar-retained implants mandibular overdentures over a one-year period of follow-up.

Materials And Methods: Thirty edentulous patients seeking for two implants bar-retained mandibular overdentures were randomly assigned into three groups as the following: Group I: 10 patients received a Co-Cr conventional casting bar, Group II: 10 patients received a Co-Cr CAD/CAM milled bar, and Group III: 10 patients received a Co-Cr CAD/CAM 3D-printed bar.

View Article and Find Full Text PDF

Metformin associates with higher myocardial perfusion reserve and survival in type 2 diabetes mellitus patients.

Sci Rep

November 2024

Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, LS2 9JT, UK.

Metformin is an antihyperglycemic used to treat type 2 diabetes mellitus (T2DM). Patients with T2DM are at increased risk of cardiovascular disease. We explored the association between metformin use and cardiovascular magnetic resonance (CMR) derived stress myocardial blood flow (MBF), myocardial perfusion reserve (MPR) and major adverse cardiovascular events (MACE; all cause death, MI, stroke, heart failure hospitalisation and coronary revascularisation) in patients with T2DM.

View Article and Find Full Text PDF

Background: Motion correction (MC) is critical for accurate quantification of myocardial blood flow (MBF) and flow reserve (MFR) from F-flurpiridaz positron emission tomography (PET) myocardial perfusion imaging (MPI). However, manual correction is time consuming and introduces inter-observer variability. We aimed to validate an automatic MC algorithm for F-flurpiridaz PET-MPI in terms of diagnostic performance for predicting coronary artery disease (CAD).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!