This technical note aims to present a recently developed computer-guided protocol characterized by titanium-reinforced stackable surgical guides during post-extractive implant placement and subsequent immediate loading. A full maxillary edentulism was rehabilitated with one-piece implants, starting from a pre-existing removable denture. 3D digital scans of the removable denture and upper and lower arches were performed. On this basis, a prototype with ideal esthetic and functional outcomes was realized and replicated into a custom-made radiological stent with markers. The superimposition of STL and DICOM files allowed virtual planning of one-piece implants in the ideal prosthetically driven position. The stackable guides, composed of a fixed base template and additional removable components, were then realized. The fixed template, initially secured with anchor pins to the bone, was no longer removed. The removable components, which were screwed to the base template, were used to perform implant surgery and immediate prosthetic loading. No surgical complications occurred, the implants achieved a minimum insertion torque of 35 Ncm, and immediate prosthetic loading was performed. The base template allowed for the maintenance of a fixed reference during the entire workflow, improving the transition between the digital project, the surgical procedure, and the prosthetic rehabilitation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10670089PMC
http://dx.doi.org/10.3390/dj11110256DOI Listing

Publication Analysis

Top Keywords

one-piece implants
12
base template
12
technical note
8
removable denture
8
removable components
8
prosthetic loading
8
computer aided
4
aided full
4
full arch
4
arch restoration
4

Similar Publications

Purpose: This study aimed to evaluate the effect of functional loading on microgaps and microleakage at implant-abutment interfaces (IAIs) in the aesthetic zone when using different abutments and to provide a clinical reference for abutment selection.

Methods: This study included 30 patients with 36 implants divided into three groups: zirconia (Zr)-one-piece custom abutment, titanium (Ti)-custom abutment, and Ti-original abutment. Scanning electron microscopy was used to examine alterations in the microgaps at the IAIs under functional loading.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the long-term outcomes of one-piece narrow-diameter implants (NDIs) and identify factors influencing marginal bone loss (MBL) around them.
  • The analysis involved 25 patients and 40 NDIs over an average of 10.5 years, with a high survival rate of 95.1% for implants and a mean MBL of 0.44 mm, primarily linked to the use of guided bone regeneration (GBR).
  • The findings suggest that NDIs perform well clinically over time, showing acceptable MBL, but further research with larger samples is recommended to confirm these results.
View Article and Find Full Text PDF

Objective: To assess the clinical, radiographic and patient-reported outcome measures, and the success of screw-retained one-piece monolithic zirconia implant-supported restorations in the posterior region during a 1-year follow-up.

Methods: In a prospective case series, 50 single molar sites in the posterior region of 41 patients with a minimum age of 18 years and sufficient bone volume for placing an implant (≥ 8 mm) and space for an anatomical restoration were included. Following prosthetic-driven digital three-dimensional treatment planning, a tissue-level implant with an internal connection was inserted during a one-stage surgical procedure.

View Article and Find Full Text PDF

The Verified Intraoral Scanning Workflow for the Full Arch Implant Patient.

Oral Maxillofac Surg Clin North Am

December 2024

Private Practice of Prosthodontics at Sheets, Paquette & Wu Dental Practice, 360 San Miguel Drive Suite #204, Newport Beach, CA 92660, USA.

The authors have questioned the accuracy of intraoral scanning when restoring the full arch implant patient. Yet clinicians use intraoral scanning (IOS) for this purpose due to the many efficiencies that the IOS workflow offers. This article describes a workflow that is used to enhance the accuracy of the intraoral scan without the need to use photogrammetry.

View Article and Find Full Text PDF

Ascending aortic replacement is a basic procedure in aortic surgery. The crucial factor is the anastomosis method, including the anastomosis site formation. The anastomosis method is usually completely different between true aneurysms and acute aortic dissection because of the difference in the fragility of the aorta.