A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Utility of the international society on thrombosis and hemostasis-bleeding assessment tool in the diagnosis of patients who suspected of platelet function disorders. | LitMetric

The ISTH-BAT is a structured bleeding assessment tool to record and help diagnose patients with possible bleeding disorders. However, a few studies evaluated the utility of ISTH-BAT in diagnosing patients with platelet function defects (PFDs). In this study, we evaluated the diagnostic utility of ISTH-BAT in predicting PFDs among patients suspected of PFDs. Forty patients suspected of PFDs and 21 normal healthy controls were evaluated by the ISTH-BAT scoring system, light transmission aggregometry (LTA), ATP-releasing assays (lumi-aggregometry), and expression of CD62P for diagnosis of PFDs. Among 40 patients suspected of PFDs, 10 were diagnosed as PFDs using lumiaggregometry and CD62P. The ISTH-BAT score in patients suspected of PFDs [(6, interquartile range (IQR) 1-8] and patients with PFDs was significantly higher than the control group (0; IQR 0-0) ( P  < 0.001). Receiver operating characteristic curves indicate that ISTH-BAT is not able to discriminate patients with PFDs from those without PFDs (areas under the curve of 0.620 (95% confidence interval 0.415-0.825). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the ISTH-BAT in predicting the presence of PFDs, respectively, were 40, 73.3, 33.3, and 78.6% in the cut-off ISTH-BAT at least 4 in adult men, at least 6 in adult women, and at least 3 in children (age < 18). The ISTH-BAT scoring system has good discriminatory power in diagnosing patients with PFDs from healthy controls but is ineffective in differentiating them from those without PFDs.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MBC.0000000000001264DOI Listing

Publication Analysis

Top Keywords

patients suspected
20
suspected pfds
16
pfds
9
assessment tool
8
patients
8
platelet function
8
utility isth-bat
8
pfds patients
8
suspected
5
isth-bat
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!