In patients with heart failure, guideline directed medical therapy improves outcomes and requires close patient monitoring. Pulmonary artery pressure monitors permit remote assessment of cardiopulmonary haemodynamics and facilitate early intervention that has been shown to decrease heart failure hospitalization. Pressure sensors implanted in the pulmonary vasculature are stabilized through passive or active interaction with the anatomy and communicate with an external reader to relay invasively measured pressure by radiofrequency. A body mass index  > 35 kg/m and chest circumference > 165 cm prevent use due to poor communication. Pulmonary vasculature anatomy is variable between patients and the pulmonary artery size, angulation of vessels and depth of sensor location from the chest wall in heart failure patients who may be candidates for pressure sensors remains largely unexamined. The present study analyses the size, angulation, and depth of the pulmonary artery at the position of implantation of two pulmonary artery pressure sensors: the CardioMEMS sensor typically implanted in the left pulmonary artery and the Cordella sensor implanted in the right pulmonary artery. Thirty-four computed tomography pulmonary angiograms from patients with heart failure were analysed using the MIMICS software. Distance from the bifurcation of the pulmonary artery to the implant site was shorter for the right pulmonary artery (4.55 ± 0.64 cm vs. 7.4 ± 1.3 cm) and vessel diameter at the implant site was larger (17.15 ± 2.87 mm vs. 11.83 ± 2.30 mm). Link distance (length of the communication path between sensor and reader) was shorter for the left pulmonary artery (9.40 ± 1.43 mm vs. 12.54 ± 1.37 mm). Therefore, the detailed analysis of pulmonary arterial anatomy using computed tomography pulmonary angiograms may alter the choice of implant location to reduce the risk of sensor migration and improve readability by minimizing sensor-to-reader link distance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10665414PMC
http://dx.doi.org/10.1038/s41598-023-47612-9DOI Listing

Publication Analysis

Top Keywords

pulmonary artery
44
pulmonary
16
artery pressure
12
heart failure
12
pressure sensors
12
artery
11
implanted pulmonary
8
pulmonary vasculature
8
size angulation
8
left pulmonary
8

Similar Publications

Background: Autosomal recessive cutis laxa type 1B (ARCL1B) is an extremely rare disease characterized by severe systemic connective tissue abnormalities, including cutis laxa, aneurysm and fragility of blood vessels, birth fractures and emphysema. The severity of this disease ranges from perinatal death to manifestations compatible with survival. To date, no cases have been reported in the Chinese population.

View Article and Find Full Text PDF

Interventional occlusion of Patent ductus arteriosus (PDA) is generally efficacious and complications such as delayed occluder displacement are infrequent. Herein, we report a case of 24-year-old female with a history of unsuccessful PDA closures, who subsequently experienced delayed occluder displacement into the left main pulmonary artery. Despite numerous unsuccessful catheter-based interventions, thoracic endovascular aortic repair (TEVAR) was successfully executed.

View Article and Find Full Text PDF

Objective: To identify the early predictors of a self-reported persistence of long COVID syndrome (LCS) at 12 months after hospitalisation and to propose the prognostic model of its development.

Design: A combined cross-sectional and prospective observational study.

Setting: A tertiary care hospital.

View Article and Find Full Text PDF

Background: Abdominal aortic aneurysm (AAA) is more common in Non-small cell lung cancer (NSCLC) patients. Considering that ruptured AAA is potentially fatal, timely management of AAA would result in long-term survival benefits. We assess the prevalence and characteristics of AAA in resectable NSCLC patients who would benefit from AAA surveillance.

View Article and Find Full Text PDF

Pulmonary sequestration is a rare congenital anomaly, characterized by aberrant lung tissue supplied by an aberrant systemic artery or arteries coursing within the inferior pulmonary ligament. The intralobar variety is the most frequent form. Clinical presentation may include recurrent haemoptysis and infection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!