A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An analytical model to measure dental implant stability with the Advanced System for Implant Stability Testing (ASIST). | LitMetric

An analytical model to measure dental implant stability with the Advanced System for Implant Stability Testing (ASIST).

J Mech Behav Biomed Mater

University of Alberta, Department of Mechanical Engineering, Edmonton, Alberta, Canada, T6G 2R3; University of Alberta, Department of Biomedical Engineering, Edmonton, Alberta, Canada, T6G 2R3. Electronic address:

Published: February 2024

A non-invasive method of quantitatively assessing dental implant stability is important to monitor its long-term health. The Advanced System for Implant Stability Testing (ASIST) is a noninvasive technique that couples the impact technique with a linear vibration model of the implant system, such that the measured signal can be used to determine a matching analytical response. The purpose of this study was to evaluate the ASIST technique by comparing stability estimates obtained from artificial implant installations with various abutments. Two Straumann dental implants were installed in four densities of uniform polyurethane foam, and the stability of each installation was measured using different healing abutments and artificial dental crowns. With the ASIST, values for the estimated interfacial stiffness increased with foam density and did not significantly change with abutment type for a specific sample. This provides evidence that the analytical model is representative of the physical system. Current methods, such as resonance frequency analysis, interpret the interface stiffness based on a single frequency measurement. With the ASIST, the measured signal provides information about the first and second modes of vibration of the implant system, both of which are influenced by the properties of the corresponding abutment. The consideration of both modes allows the technique to reliably measure the interfacial stiffness independently of the system components. As a result, the ASIST technique may provide an improved non-invasive method of measuring the stability of dental implants.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2023.106238DOI Listing

Publication Analysis

Top Keywords

implant stability
16
analytical model
8
dental implant
8
advanced system
8
system implant
8
stability testing
8
testing asist
8
non-invasive method
8
implant system
8
measured signal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!