A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Precision and safety of positioning pedicle screws in the thoracic and lumbar spine using a hand-guided aiming sleeve : A CT control study]. | LitMetric

Background: For the implantation of pedicle screws, navigation-supported systems are nowadays used more and more to avoid screw misalignment by making the direction of the screw more predictable.

Objective: Examination of the precision after instrumentation of the pedicle screw with the hand-guided aiming sleeve. The aim was to verify that the implementation of the pedicle screws is plannable and precise by using 2D X‑ray only.

Method: This retrospective study analyzed 27 consecutive trauma patients (17-84 years, 13f/14m) with vertebral body fractures. The position and precision of 108 screws, implanted using the hand-guided aiming sleeve was investigated. To determine the position the actual course of the screws was examined using the postoperative 3D CT data set (GE Optima 540, General Electric Company Boston, MA, USA; slice thickness 1.25 mm). The screws were then compared to the previously defined ideal position of the tip of the screw. In addition to the absolute and relative deviation from the ideal target point, the convergence angle and the parallelism to the cover plate were determined.

Results: Of 108 implanted pedicle screws, 90 (83%) were within target. The remaining 18 (17%) represented a clinically irrelevant screw deviation: A lateral deviation was found in 17 pedicle screws (16%) and a medial deviation in 1 (1%). The average deviation from the ideal target point in the vertebral body was 2.3 mm ventrally with a standard deviation of ± 2.3 mm. No screw misalignment or pedicle perforation was found.

Conclusion: The transcutaneous implantation of pedicle screws with a hand-guided aiming sleeve in the thoracic and lumbar spine represents a safe and precise procedure. The risk of misalignment needing a revision is lower compared to other methods of navigated screw implantation reported in the literature [1-6]. A CT-based preliminary planning is not necessary. The method is economical, special technical equipment is not required.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00113-023-01392-zDOI Listing

Publication Analysis

Top Keywords

pedicle screws
20
aiming sleeve
16
screws
9
thoracic lumbar
8
lumbar spine
8
a hand-guided aiming
8
implantation pedicle
8
screw misalignment
8
hand-guided aiming
8
vertebral body
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!