Inverse radon transform with deep learning: an application in cardiac motion correction.

Phys Med Biol

Department of Electrical Engineering and Computer Science, Florida Institute of Technology, Melbourne, FL 32901, United States of America.

Published: January 2024

. This paper addresses performing inverse radon transform (IRT) with artificial neural network (ANN) or deep learning, simultaneously with cardiac motion correction (MC). The suggested application domain is cardiac image reconstruction in emission or transmission tomography where IRT is relevant. Our main contribution is in proposing an ANN architecture that is particularly suitable for this purpose.. We validate our approach with two types of datasets. First, we use an abstract object that looks like a heart to simulate motion-blurred radon transform. With the known ground truth in hand, we then train our proposed ANN architecture and validate its effectiveness in MC. Second, we used human cardiac gated datasets for training and validation of our approach. The gating mechanism bins data over time using the electro-cardiogram (ECG) signals for cardiac motion correction.. We have shown that trained ANNs can perform motion-corrected image reconstruction directly from a motion-corrupted sinogram. We have compared our model against two other known ANN-based approaches.. Our method paves the way for eliminating any need for hardware gating in medical imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ad0eb5DOI Listing

Publication Analysis

Top Keywords

radon transform
12
cardiac motion
12
motion correction
12
inverse radon
8
deep learning
8
image reconstruction
8
ann architecture
8
cardiac
5
transform deep
4
learning application
4

Similar Publications

CoReSi: a GPU-based software for Compton camera reconstruction and simulation in collimator-free SPECT.

Phys Med Biol

January 2025

CREATIS, INSA de Lyon, Bâtiment Blaise Pascal, 7 Avenue Jean Capelle, Villeurbanne, 69621 Cedex , FRANCE.

Compton cameras are imaging devices that may improve observation of sources of γ photons. We present CoReSi, a Compton Reconstruction and Simulation software implemented in Python and powered by PyTorch to leverage multi-threading and for easy interfacing with image processing and deep learning algorithms. The code is mainly dedicated to medical imaging and for near-field experiments where the images are reconstructed in 3D.

View Article and Find Full Text PDF

Fourier energy spectrum centroid: a robust and efficient approach for shear wave speed estimation in-space.

Phys Med Biol

January 2025

Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong Special Administrative Region of China, People's Republic of China.

The propagation speed of a shear wave, whether externally or internally induced, in biological tissues is directly linked to the tissue's stiffness. The group shear wave speed (SWS) can be estimated using a class of time-of-flight (TOF) methods in the time-domain or phase speed-based methods in the frequency domain. However, these methods suffer from biased estimations or time-consuming computations, and they are especially prone to wave distortions incases.

View Article and Find Full Text PDF

A Non-Stochastic Special Model of Risk Based on Radon Transform.

Entropy (Basel)

October 2024

Faculty of Physics, Department of Mathematical Methods in Physics, University of Białystok, ul. Ciołkowskiego 1L, 15-245 Białystok, Poland.

The concept of risk is fundamental in various scientific fields, including physics, biology and engineering, and is crucial for the study of complex systems, especially financial markets. In our research, we introduce a novel risk model that has a natural transactional-financial interpretation. In our approach, the risk of holding a financial instrument is related to the measure of the possibility of its loss.

View Article and Find Full Text PDF

Veni, Vidi, Vici-When Is Home Video Seizure Monitoring Helpful?

Epilepsy Curr

May 2024

Division of Epilepsy and Clinical Neurophysiology, Department of Neurology, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA.

Seizure detection is vital for managing epilepsy as seizures can lead to injury and even death, in addition to impacting quality of life. Prompt detection of seizures and intervention can help prevent injury and improve outcomes for individuals with epilepsy. Wearable sensors show promising results for automated detection of certain seizures, but they have limitations such as patient tolerance, impracticality for newborns, and the need for recharging.

View Article and Find Full Text PDF

Visual deprivation causes enhanced eye growth and the development of myopia, which is associated with a change in the arrangement of collagen fibers within the sclera. A second harmonic generation (SHG) microscope has been used to image the collagen fibers of unstained scleral punches from the posterior part of chicken eyes. We aimed to analyze the fibrous scleral tissue and quantify the changes in collagen organization in relation to the extent of induced deprivation myopia.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!