A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Finite element analysis of artificial ankle elastic improved inserts]. | LitMetric

[Finite element analysis of artificial ankle elastic improved inserts].

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi

Department of Orthopedics, Zhangjiagang Hospital Affiliated to Soochow University, Zhangjiagang Jiangsu, 215600, P. R. China.

Published: November 2023

Objective: To discuss the influence of artificial ankle elastic improved inserts (hereinafter referred to as "improved inserts") in reducing prosthesis micromotion and improving joint surface contact mechanics by finite element analysis.

Methods: Based on the original insert of INBONE Ⅱ implant system (model A), four kinds of improved inserts were constructed by adding arc or platform type flexible layer with thickness of 1.3 or 2.6 mm, respectively. They were Flying goose type_1.3 elastic improved insert (model B), Flying goose type_2.6 elastic improved insert (model C), Platform type_1.3 elastic improved insert (model D), Platform type_2.6 elastic improved insert (model E). Then, the CT data of right ankle at neutral position of a healthy adult male volunteer was collected, and finite element models of total ankle replacement (TAR) was constructed based on model A-E prostheses by software of Mimics 19.0, Geomagic wrap 2017, Creo 6.0, Hypermesh 14.0, and Abaqus 6.14. Finally, the differences of bone-metal prosthesis interface micromotion and articular surface contact behavior between different models were investigated under ISO gait load.

Results: The tibia/talus-metal prosthesis interfaces micromotion of the five TAR models gradually increased during the support phase, then gradually fell back after entering the swing phase. The improved models (models B-E) showed lower bone-metal prosthesis interface micromotion when compared with the original model (model A), but there was no significant difference among models A-E ( >0.05). The maximum micromotion of tibia appeared at the dome of the tibial bone groove, and the ​​micromotion area was the largest in model A and the smallest in model E. The maximum micromotion of talus appeared at the posterior surface of the central bone groove, and there was no difference in the micromotion area among models A-E. The contact area of the articular surface of the insert/talus prosthesis in each group increased in the support phase and decreased in the swing phase during the gait cycle. Compared with model A, the articular surface contact area of models B-E increased, but there was no significant difference among models A-E ( >0.05). The change trend of the maximum stress on the articular surface of the inserts/talus prosthesis was similar to that of the contact area. Only the maximum contact stress of the insert joint surface of models D and E was lower than that of model A, while the maximum contact stress of the talar prosthesis joint surface of models B-E was lower than that of model A, but there was no significant difference among models A-E ( >0.05). The high stress area of the lateral articular surface of the improved inserts significantly reduced, and the articular surface stress distribution of the talus prosthesis was more uniform.

Conclusion: Adding a flexible layer in the insert can improve the elasticity of the overall component, which is beneficial to absorb the impact force of the artificial ankle joint, thereby reducing interface micromotion and improving contact behavior. The mechanical properties of the inserts designed with the platform type and thicker flexible layer are better.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10662418PMC
http://dx.doi.org/10.7507/1002-1892.202307042DOI Listing

Publication Analysis

Top Keywords

elastic improved
24
articular surface
24
improved insert
16
insert model
16
models a-e
16
model
13
artificial ankle
12
improved inserts
12
joint surface
12
surface contact
12