A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effective ventilation and chest compressions during neonatal resuscitation - the role of the respiratory device. | LitMetric

Background: The success of cardiopulmonary resuscitation (CPR) in newborns largely depends on effective lung ventilation; however, a direct randomized comparison using different available devices has not yet been performed.

Methods: Thirty-six professionals were exposed to a realistic newborn CPR scenario. Ventilation with either a bag-valve mask (BVM), T-piece, or ventilator was applied in a randomized manner during CPR using a Laerdal manikin. The primary outcome was the number of unimpaired inflations, defined as the peak of the inflation occurring after chest compression and lasting at least 0.35 s before the following chest compression takes place. The secondary outcomes were tidal volume delivered and heart compression rate. To simulate potential distractions, the entire scenario was performed with or without a quiz. Statistically, a mixed model assessing fixed effects for experience, profession, device, and distraction was used to analyze the data. For direct comparison, one-way ANOVA with Bonferroni's correction was applied.

Results: The number of unimpaired inflations was highest in health care professionals using the BVM with a mean ± standard deviation of 12.8 ± 2.8 (target: 15 within 30 s). However, the tidal volumes were too large in this group with a tidal volume of 42.5 ± 10.9 ml (target: 25-30 ml). The number of unimpaired breaths with the mechanical ventilator and the T-piece system were 11.6 (±3.6) and 10.1 (±3.7), respectively. Distraction did not change these outcomes, except for the significantly lower tidal volumes with the T-piece during the quiz.

Conclusions: In summary, for our health care professionals, ventilation using the mechanical ventilator seemed to provide the best approach during CPR, especially in a population of preterm infants prone to volutrauma.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14767058.2023.2276042DOI Listing

Publication Analysis

Top Keywords

number unimpaired
12
unimpaired inflations
8
chest compression
8
tidal volume
8
health care
8
care professionals
8
tidal volumes
8
mechanical ventilator
8
effective ventilation
4
ventilation chest
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!