AI Article Synopsis

  • The study assessed how glass ionomer cement (GIC) modified with hydroxyapatite (HAp) or calcium silicate (CaSi) influences the mineral content and mechanical properties of demineralized dentin.
  • The modified GICs released more calcium and strontium ions than regular GIC, and only the HAp version released more fluoride than the control.
  • Despite changes in compressive strength (CS) due to the modifications, none of the groups demonstrated effective remineralization of dentin compared to the negative control.

Article Abstract

Objective: to evaluate the effect a glass ionomer cement (GIC) containing hydroxyapatite (HAp) or calcium silicate (CaSi) particles on mineral content and mechanical properties of demineralized dentin. Ion release and compressive strength (CS) of the cements were also evaluated.

Methods: GIC (Fuji 9 Gold Label, GC), GIC+ 5%HAp and GIC+ 5%CaSi (by mass) were evaluated. Ion release was determined by induced coupled plasma optical emission spectroscopy (Ca/Sr) or ion-specific electrode (F) (n = 3). A composite (Filtek Z250, 3 M ESPE) was used as control in remineralization tests. Demineralized dentin discs were kept in contact with materials in simulated body fluid (SBF) at 37 °C for eight weeks. Mineral:matrix ratio (MMR) was determined by ATR-FTIR spectroscopy (n = 5). Dentin hardness (H) and elastic modulus (E) were determined by nanoindentation (n = 10). CS was tested after 24 h and 7d in deionized water (n = 12). Data were analyzed by ANOVA/Tukey test (α = 0.05).

Results: Ca and Sr release was higher for the modified materials (p < 0.05). Only GIC+ 5%HAp showed higher F release than the control (p < 0.05). All groups showed statistically significant increases in MMR, with no differences among them after 8 weeks (p > 0.05). No differences in dentin H or E were observed among groups (p > 0.05). HAp-modified GIC showed increased initial CS, while adding CaSi had the opposite effect (p < 0.05). After 7 days, GIC+ 5%CaSi presented lower CS in relation to control and GIC+ 5%HAp (p < 0.05).

Significance: GIC modification with HAp or CaSi affected CS and increased ion release; however, none of the groups showed evidence of dentin remineralization in comparison to the negative control.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2023.11.005DOI Listing

Publication Analysis

Top Keywords

glass ionomer
8
ionomer cement
8
mineral content
8
content mechanical
8
mechanical properties
8
demineralized dentin
8
ion release
8
cement calcium-releasing
4
calcium-releasing particles
4
dentin
4

Similar Publications

Objectives:  Calcium carbonate (CaCO), a major inorganic component in bones and teeth, offers potential protection against demineralization. This study investigates the effect of CaCO from shells on the expression of fibroblast growth factor 2 (FGF2), transforming growth factor-β1 (TGF-β1), and collagen type 1 in the rat dental pulp.

Materials And Methods:  The first maxillary molars of were perforated and subsequently pulp capped with CaCO extracted from shells.

View Article and Find Full Text PDF
Article Synopsis
  • The management of molar-incisor hypomineralization is complex due to varying clinical appearances and treatment needs.
  • The report details a treatment case involving a carious permanent molar using glass ionomer cement (GIC) and an occlusal replica technique.
  • After the procedure, the patient showed no symptoms, maintained good oral hygiene, and the restorative material remained intact after 12 months.
View Article and Find Full Text PDF

Statement Of Problem: Excess cement in implant-supported restorations can lead to peri-implant diseases, and its removal remains a clinical challenge. The optimum method of minimizing excess cement is unclear.

Purpose: The purpose of this in vitro study was to compare 3 cementation techniques and 3 cement types and measure excess cement.

View Article and Find Full Text PDF

This study investigated the effects of resin composites (RCs) containing surface pre-reacted glass ionomer (S-PRG) filler on the dentin microtensile bond strength (μTBS) of HEMA-free and HEMA-containing universal adhesives (UAs). Water sorption (WS) and solubility (SL), degree of conversion (DC), and ion release were measured. The UAs BeautiBond Xtreme (BBX; 0% HEMA), Modified Adhesive-1 (E-BBX1; 5% HEMA), Modified Adhesive-2 (E-BBX2; 10% HEMA), and two 2-step self-etch adhesives (2-SEAs): FL-BOND II (FBII; with S-PRG filler) and silica-containing adhesive (E-FBII) were used.

View Article and Find Full Text PDF

Evaluation of the Effects of Thermal Aging on the Surface Roughness of Novel Tooth-Colored Restorative Materials.

Dent J (Basel)

December 2024

Department of Biomedical Sciences, School of Dental Medicine, University of Nevada, Las Vegas, NV 89557, USA.

The development of composite resins has led to novel materials aimed at improving restoration longevity. This study evaluates the surface roughness of four tooth-colored restorative materials after thermal aging. Eighty Class V preparations were restored with Admira Fusion, Beautifil II, Equia Forte HT, and Filtek.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!