A case study on Sitagliptin drug products and Sitagliptin/Metformin drug products concerning contamination with N-nitrosamines was performed using two newly developed analytical methods for determination of N-nitroso-triazolopyrazine (NTTP; 7-nitroso-3-(trifluoromethyl)-5,6,7,8-tetrahydro-[1,2,4]triazolo[4,3-a]pyrazine) and its precursor triazolopyrazine (3-(trifluoromethyl)-5,6,7,8-tetrahydro-[1,2,4]triazolo[4,3-a]pyrazine). The method for determination of triazolopyrazine was previously unpublished, the method for determination of NTTP was published only for analysis of active pharmaceutical ingredient Sitagliptin and not the drug forms. Solving the N-nitrosamine contamination is requested by regulatory authorities all over the world and thus is vital for all pharmaceutical companies. The solution always requires a sensitive analytical method. Both newly developed methods use liquid chromatography coupled with mass spectrometry (single quadrupole analyzer in case of triazolopyrazine and triple quadrupole analyzer in case of NTTP). Separation of triazolopyrazine was achieved on a column Acquity CSH C18 using a mobile phase consisting of aqueous ammonium formate buffered at pH 4.2 and acetonitrile. Detection was performed using positive electrospray and selected ion monitoring at m/z 193. Separation of NTTP was achieved on a column Acquity HSS T3 using a mobile phase consisting of 0.1 % formic acid in water and methanol. Detection was performed using positive electrospray and multiple reaction monitoring at transitions m/z 222.15→42.05 (collision energy 17 eV) and m/z 222.15→192.15 (collision energy 11 eV). Two issues specific to NTTP and triazolopyrazine previously not described in scientific literature were successfully troubleshooted. Spontaneous degradation of Sitagliptin to triazolopyrazine and methyl (R)-3-amino-4-(2,4,5-trifluorophenyl)butanoate was solved by using N,N-dimethylformamide as sample solvent during development of the method for quantitation of triazolopyrazine. A bad peak shape of NTTP due to the presence of rotamers of NTTP was successfully troubleshooted by increasing column temperature. Both methods were used during an optimization study of manufacturing of Sitagliptin and Sitagliptin/Metformin drug products. The goal of the study was to decrease NTTP content in the final drug product under the strict legislative limit set by Federal Drug Agency. The efficacy of several solutions was proven, but could not be fully disclosed due to Intellectual Property Protection policy of Zentiva. Instead, a brief review of recently published strategies to cope with N-nitrosamine contamination is presented.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2023.115861DOI Listing

Publication Analysis

Top Keywords

drug products
12
triazolopyrazine
8
sitagliptin drug
8
sitagliptin/metformin drug
8
newly developed
8
nttp
8
method determination
8
n-nitrosamine contamination
8
quadrupole analyzer
8
analyzer case
8

Similar Publications

Introduction: Although there are numerous options for epilepsy treatment, its effective control continues unsatisfactory. Thus, search for alternative therapeutic options to improve the efficacy/safety binomial of drugs becomes very attractive to investigate. In this context, intranasal administration of antiseizure drugs formulated on state-of-the-art nanosystems can be a promising strategy.

View Article and Find Full Text PDF

Background: This study aimed to provide a comprehensive review of adverse events (AEs) associated with factor Xa (FXa) inhibitors in pediatric patients.

Methods: We searched PubMed, Embase, Cochrane Library, ClinicalTrials.gov, and the European Union Clinical Trials Register for English-language records from the establishment of the database up to October 17, 2023.

View Article and Find Full Text PDF

Impact of hemoadsorption with CytoSorb® on meropenem and piperacillin exposure in critically ill patients in a post-CKRT setup: a single-center, retrospective data analysis.

Intensive Care Med Exp

January 2025

Freie Universität Berlin and Humboldt-Universität Zu Berlin, Department of Anesthesiology and Intensive Care Medicine, Charité-Universitätsmedizin Berlin, Campus Benjamin Franklin, Berlin, Germany.

Purpose: CytoSorb® (CS) adsorbent is a hemoadsorption filter for extracorporeal blood purification often integrated into continuous kidney replacement therapy (CKRT). It is primarily used in critically ill patients with sepsis and related conditions, including cytokine storms and systemic inflammatory responses. Up to now, there is no evidence nor recommendation for the use of CS filters in sepsis (22).

View Article and Find Full Text PDF

Therapeutic potential of Bacillus-derived lipopeptides in controlling enteropathogens and modulating immune responses to mitigate post-weaning diarrhea in swine.

Vet Res Commun

January 2025

Departamento de Microbiología e Inmunología, Facultad de Ciencias Exactas, Físico-Químicas y Naturales, Universidad Nacional de Río Cuarto, Ruta N 36 Km 601, Río Cuarto City, 5800, Córdoba, Argentina.

Post-weaning diarrhea (PWD) is a major concern for pig producers, as stress and early weaning increase susceptibility to enteropathogens like enterotoxigenic Escherichia coli (ETEC) and Salmonella enterica subsp. enterica serovar Typhimurium (S. Typhimurium).

View Article and Find Full Text PDF

Globally, the incidence and death rates associated with cancer persist in rising, despite considerable advancements in cancer therapy. Although some malignancies are manageable by a mix of chemotherapy, surgery, radiation, and targeted therapy, most malignant tumors either exhibit poor responsiveness to early identification or endure post-treatment survival. The prognosis for prostate cancer (PCa) is unfavorable since it is a perilous and lethal malignancy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!