A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The efficacy and safety of multi-loop traction device for gastric endoscopic submucosal dissection: a single center prospective pilot study. | LitMetric

Although gastric endoscopic submucosal dissection (ESD) is widely used, the degree of difficulty varies greatly depending on the lesion. Since the multi-loop traction device (MLTD) has been suggested to shorten the procedure time in colorectal ESD, we examined the efficacy and safety of using the MLTD in gastric ESD. Thirty patients with gastric neoplasms were prospectively enrolled from February 2022 to December 2022, and the outcomes of ESD with the MLTD were evaluated. The primary outcomes were procedure time and dissection speed. The secondary outcomes were en bloc and R0 resection rates, MLTD attachment time, and complications of ESD with the MLTD. After excluding 1 patient, 29 patients (29 lesions) were treated by ESD with the MLTD. The median procedure time was 26 min (range, 9-210 min), and the median submucosal dissection speed was 39.9 mm/min (12.4-102.7 mm/min). The rate of en bloc resection was 100%, the median MLTD attachment time was 3 min (1-7 min), and none of the patients showed intraoperative or postoperative perforations. Thus, gastric ESD with the MLTD showed a favorable procedure time and dissection speed and an acceptable complication rate. Hence, the MLTD may be effective for gastric ESD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10654424PMC
http://dx.doi.org/10.1038/s41598-023-47390-4DOI Listing

Publication Analysis

Top Keywords

procedure time
16
esd mltd
16
submucosal dissection
12
gastric esd
12
dissection speed
12
mltd
9
efficacy safety
8
multi-loop traction
8
traction device
8
gastric endoscopic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!