Neuropeptides are key signaling molecules in the endocrine and nervous systems that regulate many critical physiological processes. Understanding the functions of neuropeptides in vivo requires the ability to monitor their dynamics with high specificity, sensitivity, and spatiotemporal resolution. However, this has been hindered by the lack of direct, sensitive, and noninvasive tools. We developed a series of GRAB (G protein-coupled receptor activation‒based) sensors for detecting somatostatin (SST), corticotropin-releasing factor (CRF), cholecystokinin (CCK), neuropeptide Y (NPY), neurotensin (NTS), and vasoactive intestinal peptide (VIP). These fluorescent sensors, which enable detection of specific neuropeptide binding at nanomolar concentrations, establish a robust tool kit for studying the release, function, and regulation of neuropeptides under both physiological and pathophysiological conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11205257PMC
http://dx.doi.org/10.1126/science.abq8173DOI Listing

Publication Analysis

Top Keywords

tool kit
8
kit highly
4
highly selective
4
selective sensitive
4
sensitive genetically
4
genetically encoded
4
encoded neuropeptide
4
neuropeptide sensors
4
sensors neuropeptides
4
neuropeptides key
4

Similar Publications

Development and Application of a Fully Automated Chemiluminescence Enzyme Immunoassay for the Detection of Antibodies Against Porcine Circovirus 3 Cap.

Viruses

December 2024

State Key Laboratory of Swine and Poultry Breeding Industry, National Engineering Center for Swine Breeding Industry, College of Animal Science, South China Agricultural University, Guangzhou 510642, China.

Porcine circovirus 3 (PCV3) is a small non-enveloped circovirus associated with porcine dermatitis and nephropathy syndrome (PDNS). It has occurred worldwide and poses a serious threat to the pig industry. However, there is no commercially available vaccine.

View Article and Find Full Text PDF

Objective: Gastric adenocarcinoma (GAC) is the 17th most common cancer in the UK with a 5-year survival rate of 22%. GastroPanel (Biohit Oyj; Helsinki, Finland) is an ELISA kit that measures pepsinogen I (PGI); pepsinogen II (PGII); gastrin-17 (G-17); and Helicobacter pylori IgG antibodies (Hp IgG). PGI and the PGI/PGII ratio correlate inversely with the severity of chronic atrophic gastritis (AG).

View Article and Find Full Text PDF

Biodegradable plastics, primarily aliphatic polyesters, degrade to varying extents in different environments. However, the absence of easily implementable techniques for screening microbial biodegradation potential -coupled with the limitations of non-functional omics analyses- has restricted comparative studies across diverse polymer types and ecosystems. In this study, we optimized a novel airbrushing method that facilitates functional analyses by simplifying the preparation of polyester-coated plates for biodegradation screening.

View Article and Find Full Text PDF

Objectives: Cardiovascular complications are well known in humans with autosomal dominant polycystic kidney disease (PKD), but limited data exist for cats. This study aimed to assess echocardiographic changes, cardiac troponin I (cTnI) levels and systolic blood pressure (SBP) in Persian cats with PKD to detect early cardiac abnormalities.

Methods: In total, 52 Persian and mixed-Persian cats were enrolled, with 26 cats in the control group and 26 diagnosed with PKD via ultrasound due to the unavailability of genetic testing.

View Article and Find Full Text PDF

PathCrisp: an innovative molecular diagnostic tool for early detection of NDM-resistant infections.

Sci Rep

January 2025

CrisprBits Private Limited, 3rd Floor, Plot No.-3, F-301, Ashish Complex, LSC, New Rajdhani Enclave, East Delhi, Delhi, 110092, India.

Article Synopsis
  • The study focuses on developing a rapid and accurate molecular detection system, called the PathCrisp assay, to identify infections and antibiotic resistance directly from culture samples.
  • The PathCrisp assay uses a combination of loop-mediated isothermal amplification and CRISPR-based detection, showing high sensitivity and specificity, particularly in detecting the New Delhi metallo-beta-lactamase (NDM) gene in clinical samples.
  • This novel assay provides results in about 2 hours without the need for complex equipment or extensive DNA purification, aiming to improve antibiotic treatment decisions in various healthcare settings.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!