Importance: Consumer-level sleep analysis technologies have the potential to revolutionize the screening for obstructive sleep apnea (OSA). However, assessment of OSA prediction models based on in-home recording data is usually performed concurrently with level 1 in-laboratory polysomnography (PSG). Establishing the predictability of OSA using sound data recorded from smartphones based on level 2 PSG at home is important.

Objective: To validate the performance of a prediction model for OSA using breathing sound recorded from smartphones in conjunction with level 2 PSG at home.

Design, Setting, And Participants: This diagnostic study followed a prospective design, involving participants who underwent unattended level 2 home PSG. Breathing sounds were recorded during sleep using 2 smartphones, one with an iOS operating system and the other with an Android operating system, simultaneously with home PSG in participants' own home environment. Participants were 19 years and older, slept alone, and had either been diagnosed with OSA or had no previous diagnosis. The study was performed between February 2022 and February 2023.

Main Outcomes And Measures: Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the predictive model based on the recorded breathing sounds.

Results: Of the 101 participants included during the study duration, the mean (SD) age was 48.3 (14.9) years, and 51 (50.5%) were female. For the iOS smartphone, the sensitivity values at apnea-hypopnea index (AHI) levels of 5, 15, and 30 per hour were 92.6%, 90.9%, and 93.3%, respectively, with specificities of 84.3%, 94.4%, and 94.4%, respectively. Similarly, for the Android smartphone, the sensitivity values at AHI levels of 5, 15, and 30 per hour were 92.2%, 90.0%, and 92.9%, respectively, with specificities of 84.0%, 94.4%, and 94.3%, respectively. The accuracy for the iOS smartphone was 88.6%, 93.3%, and 94.3%, respectively, and for the Android smartphone was 88.1%, 93.1%, and 94.1% at AHI levels of 5, 15, and 30 per hour, respectively.

Conclusions And Relevance: This diagnostic study demonstrated the feasibility of predicting OSA with a reasonable level of accuracy using breathing sounds obtained by smartphones during sleep at home.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10654929PMC
http://dx.doi.org/10.1001/jamaoto.2023.3490DOI Listing

Publication Analysis

Top Keywords

level psg
12
ahi levels
12
levels hour
12
obstructive sleep
8
sleep apnea
8
conjunction level
8
recorded smartphones
8
diagnostic study
8
breathing sounds
8
operating system
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!