Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The purpose of this pilot study is to compare gene expression in mucosa around dental implants with zirconia abutment to titanium and investigate presence of particles in mucosa samples and on implant heads.
Material And Methods: Ten patients with a single implant supported prosthesis connected to zirconia or titanium abutments were invited at the five-year control. A clinical examination and a survey on experience of function and appearance were conducted. A mucosa biopsy taken in close vicinity to the implant were analysed by real-time polymerase chain reaction (qPCR) and presence of particles in a scanning electron microscope/energy-dispersive X-ray spectroscope (SEM/EDX). Cytological smear samples were collected and analysed through inductively coupled plasma mass spectrometry (ICP-MS) to investigate presence of particles on implant heads.
Results: In total, 9 patients participated in the study, five with titanium abutments and four with zirconia abutments. All patients were satisfied with function and aesthetics. Titanium and iron particles were detected in mucosa biopsies. The ICP - MS analysis demonstrated presence of zirconia and titanium. Several proinflammatory genes were upregulated in the zirconia abutment group.
Conclusions: Around zirconia abutments a slight increase in proinflammatory response and amount of wear particles was seen as compared to titanium. Wear particles of titanium were present in all soft tissue samples, however zirconia particles only in the samples from implants heads/mucosa with zirconia abutments.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10645473 | PMC |
http://dx.doi.org/10.5037/jomr.2023.14302 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!