Background: Timely use of an automated external defibrillator (AED) improves outcomes in sudden cardiopulmonary arrest (SCA). Our project aims were to: 1) identify the barriers to optimal AED use in the Québec City area elementary schools; 2) create targeted educational material regarding AEDs; and 3) measure the impact of the teaching module.
Methods: Using a quality improvement in health-care framework, a survey exploring the barriers to AED use was sent to 139 elementary schools. We then developed a video teaching module on using AEDs to address these barriers. A convenience sample of 92 elementary school professionals participated in a mock scenario. Metrics related to AED use were assessed at baseline and after completing the post-teaching module. The primary outcome was the time to first shock and secondary outcomes consisted of evaluating the completion of each step required for safe and effective AED use.
Results: The barrier analysis survey received a response rate of 52.5%. Most schools reported having an AED (95%), but 48.6% indicated that no formal training was offered. After the teaching module, the appropriate use of the AED in an SCA simulation improved from 53% to 92% ( < 0.001). The average time elapsed before first shock was 66 (95% confidence interval [CI], 63-70) seconds at baseline compared with 47 (95% CI, 45-49) seconds post-teaching module ( < 0.001).
Conclusions: Lack of training, the main barrier to optimal use of AEDs in elementary schools, can be addressed through a brief video teaching module, thus improving the ability to deliver timely and effective defibrillation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642092 | PMC |
http://dx.doi.org/10.1016/j.cjcpc.2021.12.002 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!