A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of an optical sensor for the determination of phenolic compounds in environmental samples. | LitMetric

A new optical sensor was developed for the rapid sensing of total phenolic content, which is simple, cheap, and sensitive, using the Eu(III)-(NTA)-(Phen) complex [NTA = 1-(2-naphthoyl)-3,3,3-trifluoroacetone and Phen = 1,10 phenanthroline] as a luminescent probe at pH 7.5 using PIPES buffer. This method was based on luminescence quenching. The type of quenching during the reaction between the Eu(III)-(NTA)-(Phen) complex and the phenolic compounds is dynamic quenching; the binding site is close to 1, and the reaction is endothermic, spontaneous, and involves hydrophobic attraction forces. The calibration curves were plotted using a sigmoidal fit giving an LOD of 0.01 μg mL, and the correlation coefficients are more than 0.99. For the first time, the time-resolved fluorescence technique was utilized in microtiter plates to enable the determination of 96 samples within two minutes with high sensitivity and selectivity. The proposed method was applied to three industrial wastewater samples and compared with the standard method for phenolic content determination, yielding high recoveries. This is the first luminescence method based on lanthanide complexes as probes for determining the total phenolic content in water samples.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3ay01699dDOI Listing

Publication Analysis

Top Keywords

phenolic content
12
optical sensor
8
phenolic compounds
8
total phenolic
8
euiii-nta-phen complex
8
method based
8
phenolic
5
development optical
4
sensor determination
4
determination phenolic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!