Background: Keratoconus remains difficult to diagnose, especially in the early stages. It is a progressive disorder of the cornea that starts at a young age. Diagnosis is based on clinical examination and corneal imaging; though in the early stages, when there are no clinical signs, diagnosis depends on the interpretation of corneal imaging (e.g. topography and tomography) by trained cornea specialists. Using artificial intelligence (AI) to analyse the corneal images and detect cases of keratoconus could help prevent visual acuity loss and even corneal transplantation. However, a missed diagnosis in people seeking refractive surgery could lead to weakening of the cornea and keratoconus-like ectasia. There is a need for a reliable overview of the accuracy of AI for detecting keratoconus and the applicability of this automated method to the clinical setting.

Objectives: To assess the diagnostic accuracy of artificial intelligence (AI) algorithms for detecting keratoconus in people presenting with refractive errors, especially those whose vision can no longer be fully corrected with glasses, those seeking corneal refractive surgery, and those suspected of having keratoconus. AI could help ophthalmologists, optometrists, and other eye care professionals to make decisions on referral to cornea specialists. Secondary objectives To assess the following potential causes of heterogeneity in diagnostic performance across studies. • Different AI algorithms (e.g. neural networks, decision trees, support vector machines) • Index test methodology (preprocessing techniques, core AI method, and postprocessing techniques) • Sources of input to train algorithms (topography and tomography images from Placido disc system, Scheimpflug system, slit-scanning system, or optical coherence tomography (OCT); number of training and testing cases/images; label/endpoint variable used for training) • Study setting • Study design • Ethnicity, or geographic area as its proxy • Different index test positivity criteria provided by the topography or tomography device • Reference standard, topography or tomography, one or two cornea specialists • Definition of keratoconus • Mean age of participants • Recruitment of participants • Severity of keratoconus (clinically manifest or subclinical) SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register), Ovid MEDLINE, Ovid Embase, OpenGrey, the ISRCTN registry, ClinicalTrials.gov, and the World Health Organization International Clinical Trials Registry Platform (WHO ICTRP). There were no date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 29 November 2022.

Selection Criteria: We included cross-sectional and diagnostic case-control studies that investigated AI for the diagnosis of keratoconus using topography, tomography, or both. We included studies that diagnosed manifest keratoconus, subclinical keratoconus, or both. The reference standard was the interpretation of topography or tomography images by at least two cornea specialists.

Data Collection And Analysis: Two review authors independently extracted the study data and assessed the quality of studies using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. When an article contained multiple AI algorithms, we selected the algorithm with the highest Youden's index. We assessed the certainty of evidence using the GRADE approach.

Main Results: We included 63 studies, published between 1994 and 2022, that developed and investigated the accuracy of AI for the diagnosis of keratoconus. There were three different units of analysis in the studies: eyes, participants, and images. Forty-four studies analysed 23,771 eyes, four studies analysed 3843 participants, and 15 studies analysed 38,832 images. Fifty-four articles evaluated the detection of manifest keratoconus, defined as a cornea that showed any clinical sign of keratoconus. The accuracy of AI seems almost perfect, with a summary sensitivity of 98.6% (95% confidence interval (CI) 97.6% to 99.1%) and a summary specificity of 98.3% (95% CI 97.4% to 98.9%). However, accuracy varied across studies and the certainty of the evidence was low. Twenty-eight articles evaluated the detection of subclinical keratoconus, although the definition of subclinical varied. We grouped subclinical keratoconus, forme fruste, and very asymmetrical eyes together. The tests showed good accuracy, with a summary sensitivity of 90.0% (95% CI 84.5% to 93.8%) and a summary specificity of 95.5% (95% CI 91.9% to 97.5%). However, the certainty of the evidence was very low for sensitivity and low for specificity. In both groups, we graded most studies at high risk of bias, with high applicability concerns, in the domain of patient selection, since most were case-control studies. Moreover, we graded the certainty of evidence as low to very low due to selection bias, inconsistency, and imprecision. We could not explain the heterogeneity between the studies. The sensitivity analyses based on study design, AI algorithm, imaging technique (topography versus tomography), and data source (parameters versus images) showed no differences in the results.

Authors' Conclusions: AI appears to be a promising triage tool in ophthalmologic practice for diagnosing keratoconus. Test accuracy was very high for manifest keratoconus and slightly lower for subclinical keratoconus, indicating a higher chance of missing a diagnosis in people without clinical signs. This could lead to progression of keratoconus or an erroneous indication for refractive surgery, which would worsen the disease. We are unable to draw clear and reliable conclusions due to the high risk of bias, the unexplained heterogeneity of the results, and high applicability concerns, all of which reduced our confidence in the evidence. Greater standardization in future research would increase the quality of studies and improve comparability between studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10646985PMC
http://dx.doi.org/10.1002/14651858.CD014911.pub2DOI Listing

Publication Analysis

Top Keywords

topography tomography
24
keratoconus
20
studies
16
subclinical keratoconus
16
certainty evidence
16
artificial intelligence
12
detecting keratoconus
12
cornea specialists
12
refractive surgery
12
12

Similar Publications

Buccal cortical bone dimensions are crucial in dental radiology, as they impact orthodontic treatment outcomes. Changes in alveolar bone dimensions can result in malocclusion and require interdisciplinary approaches for correction. The accurate quantification of buccal bone dimensions is crucial for appropriate treatment planning and avoiding medico-legal issues.

View Article and Find Full Text PDF

Purpose: To compare the outcomes of two different surgical planning strategies for topography-guided repair of post-LASIK ectasia.

Methods: This is a case report of a patient presenting with post-LASIK ectasia. A retrospective chart review was used to collect details of the ophthalmic exam, as well as ocular imaging such as anterior segment optical coherence tomography and Scheimpflug corneal tomography.

View Article and Find Full Text PDF

Craniosynostosis, a condition marked by the premature fusion of one or more cranial sutures, exhibits diverse phenotypes. This study aims to advance the understanding of these phenotypes beyond the conventional 2-dimensional analysis by focusing on identifying indicators of increased intracranial pressure (ICP) such as bony thinning or irregularities in skull morphology. A retrospective review was conducted for all pediatric patients with midline craniosynostosis who presented to our tertiary academic center for evaluation.

View Article and Find Full Text PDF

Topography-guided, patterned, customized corneal crosslinking for non-invasive astigmatism correction.

Eye (Lond)

January 2025

Bio-manufacturing Engineering Laboratory, International Graduate School at Shenzhen, Tsinghua University, Shenzhen, Guangdong, China.

Objectives: To propose and evaluate a novel, non-invasive approach for enduring corneal astigmatism correction based on topography-guided, patterned, customized riboflavin-ultraviolet A corneal collagen crosslinking (CXL).

Methods: Astigmatism was modelled on both eyes of rabbits. A randomly selected eye of each rabbit was treated by the proposed CXL procedure with another eye as control.

View Article and Find Full Text PDF

Keratoconus (KC) is a progressive corneal disorder resulting in severe visual impairment. We aimed to determine the prevalence and corneal tomographic characteristics of KC and keratoconus suspect (KCS) in a population-based study, and to construct discrimination models with or without corneal tomography. A total of 1,544 eyes (822 participants aged ≥35 years) were evaluated using data from the Yamagata Study (2015-2017).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!