The skeletal anterior crossbite is a common malocclusion in clinic. However, there have been no reports on the maxillary sagittal expansion to correct the premaxillary hypoplasia, which greatly influences the facial morphology and masticatory function, using finite element analysis. In the present study, a three-dimensional finite element model of craniomaxillofacial complex with maxillary sagittal hypoplasia is constructed and the treatment for premaxillary hypoplasia by the sagittal screw expander appliance is simulated. The hypoplasia of the left premaxilla is more serious than that of the right and thus the size of the left part of premaxillary expander baseplate is designed to be larger than that of the right part and the loading is applied at 10° leftward to the sagittal plane and 30° forward and downward to the maxillary occlusal plane. The displacements or equivalent stress distributions of the maxilla, teeth and their periodontal ligaments, are analyzed under the loads of 5.0 N, 10.0 N, 15.0 N, and 20.0 N. Consequently, as the load increases, the displacements or equivalent stresses of the maxilla, teeth and their periodontal ligaments all increase. Almost the whole premaxilla markedly move forward, downward, and leftward while other areas in the craniomaxillofacial complex remain almost static or have little displacement. The equivalent stress concentration zone of the maxilla mainly occurs around and in front of the incisive foramina. The displacements of left premaxilla are generally greater than those of the right under the loading forces. The maximum equivalent stress on the teeth and their periodontal ligaments are 2.34E-02 MPa and 2.98E-03 MPa, respectively. Taken together, the sagittal screw expander appliance can effectively open the premaxillary suture to promote the growth of the premaxilla. An asymmetrical design of sagittal screw expander appliance achieves the asymmetric expansion of the premaxilla to correct the uneven hypoplasia and obtains the more symmetrical aesthetic presentation. This study might provide a solid basis and theoretical guidance for the clinical application of sagittal screw expander appliance in the efficient, accurate, and personalized treatment of premaxillary hypoplasia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10640993PMC
http://dx.doi.org/10.3389/fbioe.2023.1245764DOI Listing

Publication Analysis

Top Keywords

sagittal screw
20
screw expander
20
expander appliance
20
finite element
12
premaxillary hypoplasia
12
equivalent stress
12
teeth periodontal
12
periodontal ligaments
12
element analysis
8
sagittal
8

Similar Publications

Prone Transpsoas Lumbar Interbody Fusion for Degenerative Disc Disease.

JBJS Essent Surg Tech

January 2025

Department of Neurosurgery, Center for Neuroscience and Spine, Virginia Mason Medical Center, Seattle, Washington.

Background: Prone transpsoas lumbar interbody fusion (PTP) is a newer technique to treat various spinal disc pathologies. PTP is a variation of lateral lumbar interbody fusion (LLIF) that is performed with the patient prone rather than in the lateral decubitus position. This approach offers similar benefits of lateral spinal surgery, which include less blood loss, shorter hospital stay, and quicker recovery compared with traditional open spine surgery.

View Article and Find Full Text PDF

Background: Comparative studies of posterior lumbar interbody fusion with cortical bone trajectory and pedicle screw in older patients, particularly in those aged ≥ 80 years, are rare. This study aimed to retrospectively analyze the clinical and surgical outcomes following posterior lumbar interbody fusion with pedicle screw fixation compared to cortical bone trajectory in patients aged ≥ 80 years with degenerative lumbar spine disease.

Methods: We included 68 patients aged ≥ 80 years who underwent degenerative lumbar spinal surgery at our spine center between January 2011 and December 2020.

View Article and Find Full Text PDF

Background: Prone lateral spinal surgery for simultaneous lateral and posterior approaches has recently been proposed to facilitate surgical room efficiency. The purpose of this study is to evaluate the feasibility and outcomes of minimally invasive prone lateral spinal surgery using a rotatable radiolucent Jackson table.

Methods: From July 2021 to June 2023, a consecutive series of patients who received minimally invasive prone lateral spinal surgery for various etiologies by the same surgical team were reviewed.

View Article and Find Full Text PDF

Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.

View Article and Find Full Text PDF

Introduction: Interspinous devices are an alternative to instrumented fusion for the treatment of lumbar spinal stenosis (LSS) with radiological instability or deformity. The devices claim to improve clinical symptoms by indirect foraminal decompression with fewer complications and similar functional outcomes compared to conventional fusion techniques, and by avoiding a (further) deterioration of the anatomy of the spine while being less invasive than instrumented fusion.

Research Question: Do interspinous devices provide a benefit in combination with a decompression of degenerative LSS?

Material And Methods: In this observational study, 117 patients were treated by decompression surgery alone (n = 37), decompression plus instrumented spinal screw fixation and anterior cage support (n = 41) or decompression plus stabilisation with interspinous devices (n = 39).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!