Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Tritiated water (HTO), a ubiquitous byproduct of the nuclear industry, is a radioactive contaminant of major concern for environmental authorities. Although understanding spatiotemporal heterogeneity of airborne HTO vapor holds great importance for radiological safety as well as diagnosing a reactor's status, comprehensive HTO distribution dynamics inside nuclear facilities has not been studied routinely yet due to a lack of appropriate monitoring techniques. For current systems, it is difficult to simultaneously achieve high representativeness, sensitivity, and spatial resolution. Here, we developed a passive monitoring scheme, including a newly designed passive sampler and a tailored analytical protocol for the first comprehensive 3D distribution characterization of HTO inside a nuclear reactor facility. The technique enables linear sampling in any environment at a one-day resolution and simultaneous preparation of hundreds of samples within 1 day. Validation experiments confirmed the method's good metrological properties and sensitivity to the HTO's spatial dynamics. The air in TU Wien's reactor hall exhibits a range of H concentrations from 75-946 mBq m in the entire 3D matrix. The HTO release rate estimated by the mass-balance model (3199 ± 306 Bq h) matches the theoretical calculation (2947 ± 254 Bq h), suggesting evaporation as the dominant HTO source in the hall. The proposed method provides reliable and quality-controlled 3D monitoring at low cost, which can be adopted not only for HTO and may also inspire monitoring schemes of other indoor pollutants.