A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Identification of performance and cost in a new backwash method to clean the UF membrane: backwashing with low dosage of NaClO. | LitMetric

Ultrafiltration (UF) is widely used in wastewater reclamation treatments. Conventional backwashing is usually performed at regular time intervals (10-120 min) with permeate and without the addition of chemicals. Chemical enhanced backwashing (CEB) is usually applied after 70-90 filtration cycles with added chemicals. These cleaning methods cause membrane fouling and require costly chemicals. Instead of conventional backwashing, we propose herein a new backwashing method involving backwashing the effluent with low doses of sodium hypochlorite (NaClO) named as BELN. The performance and cost of UF backwashing were investigated with Beijing wastewater reclamation treatment. The results showed that the transmembrane pressure (TMP) increased from 33.2 to 48.2 kPa during hydraulic backwashing after 80 filtration cycles but increased from 33.3 to 39.3 kPa during backwashing with a low NaClO content of 20 mg/L. It was also noticed that the hydraulic-irreversible fouling index decreased from 5.58 × 10 m/L to 3.58 × 10 m/L with the new method. According to the three-dimensional fluorescence excitation-emission (3D-EEM), the response increased from 11.9 to 15.2% with BELN. Protein-like material was identified as the main component causing membrane fouling by blocking the membrane pores. The results indicated that the low dosage of NaClO effectively stripped the fouling layer. Finally, based on an economic evaluation, the capacity of the UF process was increased from 76,959 to 109,133 m/d with the new method. The amount of NaClO consumed for Beijing wastewater reclamation treatment was similarly compared with the conventional backwashing in per year under BELN. The new method has good potential for application.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11356-023-31008-3DOI Listing

Publication Analysis

Top Keywords

wastewater reclamation
12
conventional backwashing
12
backwashing
10
performance cost
8
backwashing low
8
low dosage
8
dosage naclo
8
filtration cycles
8
membrane fouling
8
beijing wastewater
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!