A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detunable wireless Litzcage coil for human head MRI at 1.5 T. | LitMetric

Detunable wireless Litzcage coil for human head MRI at 1.5 T.

NMR Biomed

Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, Tennessee, USA.

Published: March 2024

Inductively coupled radiofrequency (RF) coils are an inexpensive and simple method to realize wireless RF coils in magnetic resonance imaging (MRI), which can significantly ease the MRI scan setup and improve patient comfort because they do not require bulky components such as cables, baluns, preamplifiers, and connectors. However, volume-type wireless coils are typically operated in transmit/receive mode because detuning such coils is much more challenging due to their complex structure and multiple resonant modes. Meanwhile, adding too many detuning circuits to a wireless coil would decrease the coil's quality factor, impair the signal-to-noise ratio, and increase the cost. In this work, we proposed, constructed, and tested a novel wireless volume coil based on the Litzcage design for 1.5-T head imaging. Being an inductively coupled coil, it has a much simpler structure, resulting in a lighter weight and less bulky design. Despite its simpler structure, it exhibits comparable imaging performance with a commercial receive array, providing an alternative to conventional wired coils with a high cost and complex structure. The unique figure-of-8 conductor pattern within the rungs ensures that the proposed wireless Litzcage can be efficiently detuned with minimal detuning circuits.

Download full-text PDF

Source
http://dx.doi.org/10.1002/nbm.5068DOI Listing

Publication Analysis

Top Keywords

wireless litzcage
8
inductively coupled
8
wireless coils
8
complex structure
8
detuning circuits
8
simpler structure
8
coils
5
wireless
5
detunable wireless
4
coil
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!