Intraocular lens power calculation: angle κ and ocular biomechanics.

J Cataract Refract Surg

From the Serviço de Oftalmologia, Centro Hospitalar Universitário do Porto, Porto, Portugal (Marques, Baptista, Ribeiro, Menéres, Beirão); Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto, Portugal (Baptista, Menéres, Beirão).

Published: April 2024

Purpose: To study the effect of ocular biomechanics on the prediction error of intraocular lens (IOL) power calculation.

Setting: Centro Hospitalar Universitário do Porto, Porto, Portugal.

Design: Prospective longitudinal study.

Methods: This study included 67 subjects. Before cataract surgery subjects underwent biometry with IOLMaster 700 and biomechanical analysis with Corvis Scheimpflug technology. The targeted spherical equivalent was calculated with SRK-T and Barrett Universal II. Associations between prediction error (PE), absolute prediction error (AE), and biometric and biomechanical parameters were performed with stepwise multivariate linear correlation analysis.

Results: Using the SRKT formula, there was association between PE and Corvis Biomechanical Index (CBI, B = -0.531, P = .011) and between AE and the horizontal offset between the center of the pupil and the visual axis (angle κ, B = -0.274, P = .007). Considering the Barret Universal II formula, PE was independently associated with anterior chamber depth ( B = -0.279, P = .021) and CBI ( B = -0.520, P = .013) and AE was associated with angle κ ( B = -0.370, P = .007).

Conclusions: A large angle κ may reduce the predictability of IOL power calculation. Ocular biomechanics likely influence the refractive outcomes after IOL implantation. This study showed that eyes with softer corneal biomechanics had more myopic PE. This may relate to anteriorization of the effective lens position. Dynamic measurements may be the way to progress into future formulas.

Download full-text PDF

Source
http://dx.doi.org/10.1097/j.jcrs.0000000000001362DOI Listing

Publication Analysis

Top Keywords

ocular biomechanics
12
prediction error
12
intraocular lens
8
power calculation
8
iol power
8
lens power
4
angle
4
calculation angle
4
angle ocular
4
biomechanics
4

Similar Publications

Purpose: To investigate long-term corneal biomechanical changes in thin corneas after small incision lenticule extraction (SMILE).

Methods: Patients with indications for SMILE were enrolled in this study between November 2017 and March 2018. Patients were matched for age, spherical diopter, cylinder, spherical equivalent (SE), and lenticule thickness (LT), and then categorized into the thin cornea group (preoperative thinnest central corneal thickness [CCT] of 500 µm or less, 32 eyes) or normal cornea group (CCT of greater than 500 µm, 32 eyes).

View Article and Find Full Text PDF

Age-Related Changes in Lens Elasticity Contribute More to Accommodative Decline Than Shape Change.

Invest Ophthalmol Vis Sci

January 2025

Faculty of Health, Medicine and Social Care, Medical Technology Research Centre, Anglia Ruskin University, Bishops Hall Lane, Chelmsford, United Kingdom.

Purpose: To determine whether lens biomechanical or geometric changes contribute to the decline in the accommodative capacity of the human eye, and to examine any differences in zonular function between different age groups.

Methods: Eighteen finite element whole eye models were developed to simulate the accommodative process. Six models were constructed in each of the two age cohorts, from the fourth and the sixth decades of life using data from ex vivo human lenses.

View Article and Find Full Text PDF

Marfan syndrome is an inherited connective tissue disorder that affects the cardiovascular, musculoskeletal, and ocular systems. It is caused by pathogenic variants in the fibrillin-1 gene (). Fibrillin is a primary component of microfibrils, which are found throughout the extracellular matrix (ECM) and provide elasticity and resilience to connective tissue.

View Article and Find Full Text PDF

Inducing cylindrical and spherical defocus after implantation with new generation intraocular lenses improves intermediate and near visual acuity.

Sci Rep

December 2024

Imaging, Biomechanics and Mathematical Modelling Solutions Lab, Narayana Nethralaya Foundation, Bangalore, India.

An induced cylinder and spherical power after implantation with an extended depth of focus (EDOF) and enhanced monofocal intraocular lens (IOL) could improve distance, intermediate (60 cm) and near (40 cm) visual acuity (VA). In this prospective study, forty eyes with Eyhance EDOF IOL (Johnson and Johnson, USA) and 40 eyes with Vivity EDOF IOL (Alcon Laboratories Inc. USA) were included.

View Article and Find Full Text PDF

Unlabelled: The scientific and practical interest in studying the biomechanical characteristics of the lens capsule, on the one hand, is associated with its anatomical significance in modern microinvasive phaco surgery, and on the other hand, with investigation of the mechanisms of lens curvature changes during accommodation. Selective study of the biomechanical properties of the lens capsule aims to identify characteristics of various regions and surfaces of the capsule.

Purpose: This study is a comparative analysis of age-related changes in the biomechanical properties of the anterior (AC) and posterior (PC) lens capsules in humans.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!