Digital workflows have become integral in orthodontic diagnosis and therapy, reducing risk factors and chair time with one-visit protocols. This study assessed the transfer accuracy of fully digital planned insertion guides for orthodontic mini-implants (OMIs) compared with freehanded insertion. Cone-beam computed tomography (CBCT) datasets and intraoral surface scans of 32 cadaver maxillae were used to place 64 miniscrews in the anterior palate. Three groups were formed, two using printed insertion guides (A and B) and one with freehand insertion (C). Group A used commercially available customized surgical templates and Group B in-house planned and fabricated insertion guides. Postoperative CBCT datasets were superimposed with the planning model, and accuracy measurements were performed using orthodontic software. Statistical differences were found for transverse angular deviations (4.81° in A vs. 12.66° in B and 5.02° in C, = 0.003) and sagittal angular deviations (2.26° in A vs. 2.20° in B and 5.34° in C, = 0.007). However, accurate insertion depth was not achieved in either guide group; Group A insertion was too shallow (-0.17 mm), whereas Group B insertion was deeper (+0.65 mm) than planned. Outsourcing the planning and fabrication of computer-aided design and computer-aided manufacturing insertion guides may be beneficial for certain indications; particularly, in this study, commercial templates demonstrated superior accuracy than our in-house-fabricated insertion guides.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10647273 | PMC |
http://dx.doi.org/10.3390/jcm12216782 | DOI Listing |
JAMA Otolaryngol Head Neck Surg
January 2025
Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, Tennessee.
Importance: Cochlear implants enable improvements in speech perception, but music perception outcomes remain variable. Image-guided cochlear implant programming has emerged as a potential programming strategy for increasing the quality of spectral information delivered through the cochlear implant to improve outcomes.
Objectives: To perform 2 experiments, the first of which modeled the variance in music perception scores as a function of electrode positioning factors, and the second of which evaluated image-guided cochlear implant programming as a strategy to improve music perception with a cochlear implant.
Alzheimers Dement
December 2024
University of Pittsburgh, Pittsburgh, PA, USA.
Background: Employing a custom 60-channel single-transmit/32-channel receive Tic-Tac-Toe (TTT) coil in 7T MRI imaging has enhanced the resolution and contrast for identifying White Matter Hyperintensities (WMHs), which are critical markers in Alzheimer's disease and related dementias (AD/ADRD).
Method: The method involves resecting the left hemisphere of the brain, excluding the cerebellum, followed by embalming in 10% formalin. 1.
Acta Chir Orthop Traumatol Cech
January 2025
Neurochirurgická klinika Fakultní nemocnice Olomouc.
Purpose Of The Study: The annual number of spinal fusion procedures has been increasing and is well documented worldwide. The O-arm is slowly becoming the standard for transpedicular screw insertion. The accuracy and safety of this method have been confirmed by many studies.
View Article and Find Full Text PDFBiomed Eng Lett
January 2025
Colorectal Cancer Center, Kyungpook National University Chilgok Hospital, Daegu, Republic of Korea.
In recent years, robotic assistance has become increasingly used and applied in minimally invasive surgeries. A new cooperative surgical robot system that includes a joystick-guided robotic scope holder was developed in this study, and its feasibility for use in minimally invasive abdominal surgery was evaluated in a preclinical setting. The cooperative surgical robot consists of a six-degree-of-freedom collaborative robot arm and a one-degree-of-freedom bidirectional telescopic end-effector specializing in surgical assistance.
View Article and Find Full Text PDFNagoya J Med Sci
November 2024
Department of Neurosurgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Selecting an appropriate microcatheter tip shape for paraclinoid aneurysms is difficult. Therefore, we devised an original simple and uniform three-dimensional (3D) spiral-shaping method of microcatheter and validated the characteristics and usefulness of this method for coil embolization of paraclinoid aneurysms using patient-specific silicone models. These silicone models were produced based on clinical data from four patients with four paraclinoid aneurysms that underwent endovascular treatment using the 3D spiral-shaping method.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!