A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Non-rigid-registration-based positioning and labelling of triaxial OPMs on a flexible cap for wearable magnetoencephalography. | LitMetric

Non-rigid-registration-based positioning and labelling of triaxial OPMs on a flexible cap for wearable magnetoencephalography.

J Neurosci Methods

Center for MRI Research, Peking University, Beijing 100871, China; Beijing City Key Laboratory for Medical Physics and Engineering, Institution of Heavy Ion Physics, School of Physics, Peking University, Beijing 100871, China; Changping Laboratory, Beijing 102206, China; McGovern Institute for Brain Research, Peking University, Beijing 100871, China; National Biomedical Imaging Center, Peking University, Beijing 100871, China. Electronic address:

Published: January 2024

Background: Recent advances in highly sensitive miniaturized optically pumped magnetometers (OPMs) have enabled the development of wearable magnetoencephalography (MEG) offering great flexibility in experimental setting. The OPM array for wearable MEG is typically attached to a flexible cap and exhibits a variable spatial layout across different subjects, which imposes challenges concerning the efficient positioning and labelling of OPMs.

New Method: A pair of reflective markers are affixed to each triaxial OPM sensor above its cable to determine its location and sensitive axes. A non-rigid registration of optically digitized marker locations with a pre-labelled template of marker locations is performed to map newly digitized markers to OPMs.

Results: The positioning and labelling of 66 OPM sensors could be completed within 35 s. Across ten experiments, all OPMs were accurately labelled, and the mean test-retest errors were 0.48 mm for sensor locations and 0.20 degree for sensitive axes. By combining six OPMs' positions with their respective recordings, magnetic dipoles inside a phantom were located with a mean error of 5.5 mm, and the best fitted dipole for MEG with auditory stimuli presented was located on a subject's primary auditory cortex.

Comparison With Existing Methods: The proposed method reduces the reliance on error-prone and laborious manual operations inherent in existing methods, therefore significantly improving the efficiency of OPM positioning and labelling on a flexible cap.

Conclusion: We developed a method for the precise and rapid positioning and labelling triaxial OPMs on a flexible cap, thereby facilitating the practical implementation of wearable OPM-MEG.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jneumeth.2023.110010DOI Listing

Publication Analysis

Top Keywords

positioning labelling
20
flexible cap
12
labelling triaxial
8
triaxial opms
8
opms flexible
8
wearable magnetoencephalography
8
sensitive axes
8
marker locations
8
existing methods
8
labelling
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!